GE P&W E-Series Reverse Osmosis - E8 Series 60 Hz User Manual
E8 series 60 hz, General properties
Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
FS1129EN.doc Jul-13
E8 Series 60 Hz
Reverse Osmosis Machine 57,000 to 144,000 gallons per day
Figure 1: E8 Series 60 Hz
When you mention reverse osmosis (RO), GE’s Water
& Process Technologies is the first name to come to
mind. Our E-series RO machines (Figure 1) are de-
signed for durable operation, high quality product
water production, easy installation and straightforward
control.
General Properties
Typical Applications
Process ingredient water
Safe drinking water
Boiler feed water
Ion exchange pre-treatment
Standard Economy Features
Energy saving 400 ft
2
(37.2 m
2
) membrane
elements
SS high-pressure piping
1-micron pre-filter and SS housing
Automatic inlet shut-off valve
AccuTrak* RO microprocessor controller
-
Permeate and concentrate paddlewheel flow
sensors
-
Permeate conductivity sensor
-
Permeate tank level monitoring
-
SD card for collection of operating data
-
ALARMS: Low inlet pressure, high temperature,
high permeate conductivity, motor fault, and
fill-time exceeded
-
Remote machine on/off capability
Feed water flush on shut down
Panel-mounted pre-filter, post-filter, primary, and
final pressure gauges
Deluxe (DLX) Features – in addition to ECN
features
Inlet pH sensor
Chemical dosing pump for antiscalant dosing or pH
adjustment
Clean-In-Place pump plumbed, wired and mount-
ed; remote tank
ALARMS: Same as above plus high/low inlet pH,
high permeate pressure
Table 1: Operating Parameters
Operating Pressure
200-250 psig (13.8-
17.2 bar)
Maximum Recovery
75%
Nominal Rejection
95-98%
Operating Temperature
55-85
F (13-30
C)
Minimum Inlet Pressure
30 psig (2 bar)
Design Temperature
77
F (25
C)