FS1089EN 0603
Table 4: Integrity Testing
Additional Information
• Memtrex-MP-E filters with polypropylene
components may be autoclaved (121°C, 30
minute cycles) or in situ steam sterilized (125°C,
30 minute cycles) for a maximum accumulated
exposure of 10 hours. Memtrex-MP-E filters with
polyethylene hardware must not be autoclaved
or in situ steam sterilized. Alternatively, the
filters may be sanitized with compatible chemi-
cal agents.
• The component materials of Memtrex-MP-E fil-
ters are suitable for use in articles intended for
repeated food contact as specified in the United
States Code of Federal Regulations, Title 21.
Memtrex-MP-E filters meet the test criteria for
USP24 class VI-121°C Plastics and pass the
MEM Elution Cytotoxicity Test.
• Aqueous extracts from Memtrex-MP-E filters
contain less than 0.25 EU/ml. The filters typi-
cally exhibit low levels of non-volatile residues.
The filters rinse to less than 5 ppb TOC and less
than 5 ppb trace metals in 25 min at 2.5 gpm
per 10" module in UPDI water.
• Table 6 provides more information on ordering
Memtrex MP-E filters.
Table 6: Ordering Information
Table 5: Flow Performance in Clean Water
1
1
Data based on 10” length filter