beautypg.com

GE P&W Spiral Wound Membranes - PW Series User Manual

Pw series, Fact sheet, Table 1: element specification

background image

Fact Sheet

Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.

* Trademark of General Electric Company; may be registered in one or more countries.

©2013, General Electric Company. All rights reserved.

FS1287EN.doc Nov-13




PW Series

Industrial Ultrafiltration – Post treatment of RO and NF

The P-Series family of polyethersulfone ultrafiltra-
tion membrane elements are characterized by a
10,000 molecular weight cut-off and greater than
96% rejection of Cytochrome-C (13,300 MW pro-
tein). PW Elements are used for pretreatment of
process water, post treatment of ultrapure
water and for the removal of organics.

Table 1: Element Specification

Membrane

P-Series, Polyethersulfone

Model

Spacer mil

(mm)

Active area

ft

2

(m

2

)

Outer wrap

Part

number

PW2540C30

30 (0.76)

16 (1.5)

Cage

1207350

PW2540F30

30 (0.76)

25 (2.3)

Fiberglass

1207352

PW2540F50

50 (1.27)

17 (1.6)

Fiberglass

1207351

PW4025C

50 (1.27)

50 (4.6)

Cage

1207367

PW4025T

50 (1.27)

50 (4.6)

Tape

1207369

PW4040C30

30 (0.76)

91 (8.4)

Cage

1207372

PW4040C50

50 (1.27)

62 (5.8)

Cage

1207371

PW4040F30

30 (0.76)

85 (7.9)

Fiberglass

3050051

PW8040C50

50 (1.27)

264 (24.5)

Cage

1207399

PW8040F30

30 (0.76)

354 (39.2)

Fiberglass

1207404

PW8040F50

50 (1.27)

279 (25.9)

Fiberglass

1207403

PW8340C50

50 (1.27)

290 (27)

Cage

1223936

Figure 1: Element Dimensions Diagram – Female

Figure 2: Element Dimensions Diagram – Male


Table 2: Dimensions and Weight

Model

1

Dimensions, inches (cm)

Boxed

A

B

2

C

3

Weight

lbs (kg)

PW2540

40.0

(101.6)

0.75

(1.9) OD

2.4

(6.1)

4

(1.8)

PW4025

25.0

(63.5)

0.625

(1.59)

3.9

(9.9)

5

(2.3)

PW4040C

38.75

(98.4)

0.625

(16)

3.9

(9.8)

9

(4.1)

PW4040F

40.0

(101.6)

0.75

(1.90) OD

3.9

(9.9)

8

(3.5)

PW8040

40.0

(101.6)

1.125

(2.86)

7.9

(20.1)

29

(13.2)

PW8340

40.0

(101.6)

1.138

(2.89)

8.3

(21.1)

42

(19.1)

1

These elements are bagged dry before shipping.

2

Internal diameter unless specified OD (outside diameter).

3

The element diameter (dimension C) is designed for optimum performance in GE

pressure vessels. Other pressure vessel dimension and tolerance may result in
excessive bypass and loss of capacity.

Table 4: Operating and CIP parameters

Typical Operating Pressure

80-135 psig (555 – 931 kPa)

Typical Operating Flux

10-25GFD (15-40LMH)

Maximum Operating Pressure

200 psig (1,379 kPa)

Maximum Temperature

Continuous operation: 122°F (50°C)
Clean In Place (CIP): 122°F (50°C)

pH Range

Continuous operation: 4.0-11.0,
Clean In Place (CIP): 2.0-11.5

Maximum Pressure Drop

Over an element: 12 psig (83 kPa)
Per housing: 50 psig (345 kPa)

Chlorine Tolerance

5,000+ ppm-days