Table 3: Operational Limits

Table 4: Integrity Testing

Table 5: Flow Performance in Clean Air

1

Table 6: Flow Performance in Clean Water

1

1

Data based on 10” length filter

Table 7: Ordering Information

Additional Information

Memtrex FE filters may be autoclaved or in situ

steam sterilized (up to 257°F [125°C], 30-minute
cycles) for a maximum accumulated exposure
of 10 hours. Filters which are steam sterilized
must have stainless steel insert supported

o-ring adaptors. Alternatively, the filters may be
sanitized with compatible chemical agents.

GE certifies that the material contained in its

Memtrex MP pleated filters meet U.S. FDA

requirements for food contact under the appli-
cable regulations in 21 CFR. For further informa-
tion, contact GE technical services. Memtrex MP
filters meet the test criteria for USP class VI-
121°C Plastics.

Aqueous extracts from Memtrex MP filters con-

tain less that 0.25 EU/ml. The filters typically
exhibit low levels of non-volatile residues.

GE filter cartridges are designed and manufac-

tured for resistance to a wide range of chemical
solutions. Conditions will vary with each appli-
cation and users should carefully verify chemi-
cal compatibility. Please contact your GE
distributor for more information.

Table 7 provides additional ordering information.