beautypg.com

GE P&W Spiral Wound Membranes - CG Series User Manual

Cg series, Fact sheet, Table 1: element specification

background image

Fact Sheet

Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.

* Trademark of General Electric Company; may be registered in one or more countries.

©2013, General Electric Company. All rights reserved.

FS1267EN.doc Nov-13



CG Series

High Flux Brackish Water RO Elements (Cellulose Acetate)

The C-Series family, a triacetate/diacetate blend,
has a higher flux and better mechanical stability
than standard cellulose acetate. C-Series elements
offer an increased chlorine resistance compared to
thin-film elements.

CG High Flux Elements are used for brackish water
desalination and process stream concentration.

Table 1: Element Specification

Membrane

C-series, cellulose acetate

Model

Average

permeate flow

gpd (m3/day)

1,2

Average NaCl

rejection

1,2

Minimum NaCl

rejection

1,2

CG8040F

7,300 (27.6)

93.0%

85.0%

1

Average salt rejection after 24 hours operation. Individual flow rate may vary

+25%/-15%.

²Testing conditions: 500 ppm NaCl solution at 210 psi (1,448 kPa) operating pres-
sure, 77°F, pH 6.5 and 15% recovery.

Model

Active area

ft

2

(m

2

)

Outer wrap

Part

number

CG8040F

350 (32.5)

Fiberglass

1206896

Figure 1: Element Dimensions Diagram - Female

Model²

Dimensions, inches (cm)

Boxed

A

B

1

C

3

Weight

lbs (kg)

CG8040F

40.0

(101.6)

1.125

(2.86)

7.9

(20.1)

32

(14.5)

1

Internal diameter unless specified OD (outside diameter).

²These elements are dried then bagged before shipping.

3

The element diameter (dimension C) is designed for optimum performance in GE

pressure vessels. Others pressure vessel dimension and tolerance may result in
excessive bypass and loss of capacity.

Table 3: Operating and CIP parameters

Typical Operating Pressure

60-200 psi (414-1,379 kPa)

Typical Operating Flux

10-18 GFD (17-30 LMH)

Maximum Operating Pressure

450 psi (3,103 kPa)

Maximum Temperature

Continuous operation: 86°F (30°C)
Clean-In-Place (CIP): 86°F (30°C)

pH Range

Continuous operation: 5.0-6.5,
Clean-In-Place (CIP): 3.0-8.0

Maximum Pressure Drop

Over an element: 12 psi (83 kPa)
Per housing: 50 psi (345 kPa)

Chlorine Tolerance

1 ppm maximum continuous
30 ppm for 30 min. during sanitization

Feedwater

NTU < 1
SDI < 5