GE P&W Spiral Wound Membranes - AG HR Series User Manual
Ag hr seri, High rejection brackish water ro elements, Fact sheet

Fact Sheet
AG HR Seri
e
s
High Rejection Brackish Water RO Elements
The A-Series family of proprietary thin-film reverse
osmosis membrane is characterized by high flux
and high sodium chloride rejection. AG HR brackish
water elements are selected when high rejection
and operating pressures as low as 200 psi (1,379
kPa) are desired. These elements are recommended
for brackish water with salt concentration (TDS) lev-
els between 1,000 and 10,000mg/l or when very
high salt rejection of monovalent ions is required.
Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2011, General Electric Company. All rights reserved.
FSpwAGHRSeries_EN Feb-11
Table 1: Element Specification
1
Average salt rejection after 24 hours operation. Individual flow rate
may vary +25%/-15%.
2
Testing conditions: 2,000ppm NaCl solution at 225psi (1,550kPa) oper-
ating pressure, 77°F (25°C), pH7 and 15% recovery.
Model
Active area
ft
2
(m
2
)
Outer wrap
Part
number
AG-90
90 (8.4)
Fiberglass
3056665
AG-365
365 (33.9)
Fiberglass
3056666
AG-400
400 (37.2)
Fiberglass
3056667
AG-400, 34
400 (37.2)
Fiberglass
3056668
AG-440
440 (40.9)
Fiberglass
3056669
AG-1600
1600 (148.6)
Fiberglass
3056670
Table 2: Operating and CIP parameters
3
SDI is measured on a non-linear scale using a 0.45 micron filter paper.
Additionally, finer colloids, particulates and microorganisms that pass
through the filter paper and not measured in the SDI test, will poten-
tially foul the RO element. For performance consistency and project
warranty, please use Winflows projection software and consult your
Filters with Membranes representative.
Figure 1a: Element Dimensions Diagram – Male
Figure 1b: Element Dimensions Diagram – Female
Membrane
Thin-film membrane (TFM*)
Model
Average
permeate flow
gpd (m3/day)
1,2
Average
NaCl
rejection
1,2
Minimum
NaCl
rejection
1,2
AG-90
2200 (8.3)
99.8%
99.3%
AG-365
9600 (36.3)
99.8%
99.3%
AG-400
10500 (39.7)
99.8%
99.3%
AG-400, 34
10500 (39.7)
99.8%
99.3%
AG-440
11500 (43.5)
99.8%
99.3%
AG-1600
42000 (159.0)
99.8%
99.3%
Typical Operating Pressure
200 psi (1,380 kPa)
Typical Operating Flux
10-20GFD (15-35LMH)
Maximum Operating Pressure 600 psi (4,137 kPa)
Maximum Temperature
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
pH range
Optimum rejection: 7.0-7.5,
Continuous operation 4.0-11.0,
Clean-In-Place (CIP): 2.0-11.5
Maximum Pressure Drop
Over an element: 12 psi (83 kPa)
Per housing: 50 psi (345 kPa)
Chlorine Tolerance
1,000+ ppm-hours,
dechlorination recommended
Feedwater
3
NTU < 1
SDI < 5