beautypg.com

GE P&W Spiral Wound Membranes - MUNI RO HR Series User Manual

Muni ro hr series, Fact sheet, Table 1: element specification

background image

Fact Sheet

Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.

* Trademark of General Electric Company; may be registered in one or more countries.

©2013, General Electric Company. All rights reserved.

FSsmMUNI_RO_HR_EN.doc Jul-13



MUNI RO HR Series

Reverse Osmosis High Rejection Membrane Elements for
Municipal Drinking Water Plants

Engineered to treat municipal potable water with
high total dissolved solids, the MUNI RO HR series
enables drinking water processes to achieve an en-
hanced salt rejection.
MUNI RO HR series membrane elements are the
solution for purification of drinking water that pro-
vides the benefits of both high rejection.
MUNI RO HR elements feature a FRP outer wrap
and female end connections and are tested and
certified by NSF international against NSF/ANSI
Standard 61 for material requirements only.

Table 1: Element Specification

Membrane

Thin-film membrane (TFM*)

Model

Average

permeate flow

gpd (m3/day)

1,2

Average NaCl

rejection

1,2

Minimum NaCl

rejection

1,2

MUNI-RO-400-HR

10,500 (39.7)

99.8

99.3

MUNI-RO-430-HR

11500 (43.5)

99.8

99.3

1

Average salt rejection after 24 hours operation. Individual flow rate may vary

+25%/-15%.
²Testing conditions: 2,000ppm NaCl solution at 225psi (1,550kPa) operating pres-
sure, 77°F (25°C), pH7 and 15% recovery.

Model

Active area

ft

2

(m

2

)

Outer wrap

Part

number

MUNI-RO-400-HR

400 (37.2)

Fiberglass

3051521

MUNI-RO-430-HR

440 (40.9)

Fiberglass

3051522

Figure 1: Element Dimensions Diagram

Table 2: Dimensions and Weight

Model

Dimensions, inches (cm)

Boxed

A

B

2

C

Weight

lbs (kg)

MUNI-RO-***-HR

40.0

(101.6)

1.125

(2.86)

7.9

(20.1)

35

(16)

1

These elements are bagged wet (WT) before shipping.

2

Internal diameter unless specified OD (outside diameter).

Table 3: Operating and CIP parameters

Typical Operating Pressure

200psi (1,379kPa)

Typical Operating Flux

10-20GFD (15-35 LMH)

Maximum Operating Pressure

600psi (4,137kPa)

Maximum Temperature

Continuous operation: 122°F (50°C),
Clean In Place (CIP): 122°F (50°C)

Minimum Crossflow

30gpm (6.8m

3

/hr)

pH Range

Continuous operation: 4.0-11.0,
Clean In Place (CIP): 2.0-11.5

Maximum Pressure Drop

Over an element: 12psi (83kPa)
Per housing: 50psi (345kPa)

Chlorine Tolerance

1,000+ ppm-hours,
dechlorination recommended,

Feedwater

NTU < 1
SDI < 5

Recommended single element
recovery

< 15 %