beautypg.com

GE P&W SeaPRO Series 60 Hz 45,000 ppm NaCl 20-60 gpm User Manual

Seapro* series 60 hz, Basic features (bas), Premium features (pre)

background image

Fact Sheet

Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.

* Trademark of General Electric Company; may be registered in one or more countries.

©2013, General Electric Company. All rights reserved.

pfe1007en.doc Jul-13


SeaPRO* Series 60 Hz

Seawater Desalination Machines 45,000 ppm NaCl
20-60 gpm (4.5-13.6 m

3

/hr)

Basic Features (BAS)

GE Fanuc Quick Panel 6-inch, 6-inch color dis-
play, Primarily text operating screens,
Touchscreen controls

GE Fanuc Micro VersaMax, Communication:
RS232/DH485, Analog output: 6 points

4-20 mA instruments displayed on instrument
center

Variable frequency drive (VFD) for high pres-
sure pump

Stand alone master control enclosure, skid
mounted local control enclosure with terminal
strips

Premium Features (PRE)

GE Fanuc QuickPanel 12-inch, 12-inch color
display, Text and pictorial operating screens,
Touchscreen controls

GE Fanuc VersaMax Communication: RS232
/DH485/Ethernet, Analog output: 4 points

4-20 mA instruments on PanelView

Primary and final pressure transmitters

Variable frequency drive (VFD) for high pres-
sure pump

Automated valves and control for full perme-
ate flush upon shut down

Stand alone master control enclosure, skid
mounted local control enclosure w/remote I/O

Instrumentation

Flow Meters ................................. Permeate, concentrate
Conductivity ............................................................ Permeate
pH .......................................................................................... Feed
Pressure ................ Pre-filter, post-filter, primary, final,

permeate, concentrate,pump discharge

(PRE Feature = Primary, Final transmitter)

Instrumentation (continued)
Pressure Switch............ Feed, permeate, concentrate
Instrument center ............................. Thornton 770 MAX

Options Available

Allen Bradley control system

Multi-Media filters

Clean-in-Place (CIP) units

Chemical feed systems

Documentation Included

Operation and maintenance manual

Control narrative

Drawings: piping and instrumentation, electri-
cal and general dimensional

Operating Parameters

Recovery .............................................................................. 35%
Design temp. ....................................................... 77ºF (25ºC)
Design Feed TDS. .................................. 45,000 ppm NaCl
Operating range ................... 35 to 85ºF (1.6 to 29.4ºC)
Minimal inlet pressure ................................. 30 psi (2 Bar)

Materials of Construction

High-pressure piping .................. Sch. 10, Duplex 2205

Stainless Steel

Low-pressure piping ...................................... Sch. 80, PVC
Frame .................................................. Painted carbon steel
Local Enclosure ............................................ FRP, NEMA 4X