GE P&W SeaPRO Series 60 Hz 45,000 ppm NaCl 20-60 gpm User Manual
Seapro* series 60 hz, Basic features (bas), Premium features (pre)
Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
pfe1007en.doc Jul-13
SeaPRO* Series 60 Hz
Seawater Desalination Machines 45,000 ppm NaCl
20-60 gpm (4.5-13.6 m
3
/hr)
Basic Features (BAS)
GE Fanuc Quick Panel 6-inch, 6-inch color dis-
play, Primarily text operating screens,
Touchscreen controls
GE Fanuc Micro VersaMax, Communication:
RS232/DH485, Analog output: 6 points
4-20 mA instruments displayed on instrument
center
Variable frequency drive (VFD) for high pres-
sure pump
Stand alone master control enclosure, skid
mounted local control enclosure with terminal
strips
Premium Features (PRE)
GE Fanuc QuickPanel 12-inch, 12-inch color
display, Text and pictorial operating screens,
Touchscreen controls
GE Fanuc VersaMax Communication: RS232
/DH485/Ethernet, Analog output: 4 points
4-20 mA instruments on PanelView
Primary and final pressure transmitters
Variable frequency drive (VFD) for high pres-
sure pump
Automated valves and control for full perme-
ate flush upon shut down
Stand alone master control enclosure, skid
mounted local control enclosure w/remote I/O
Instrumentation
Flow Meters ................................. Permeate, concentrate
Conductivity ............................................................ Permeate
pH .......................................................................................... Feed
Pressure ................ Pre-filter, post-filter, primary, final,
permeate, concentrate,pump discharge
(PRE Feature = Primary, Final transmitter)
Instrumentation (continued)
Pressure Switch............ Feed, permeate, concentrate
Instrument center ............................. Thornton 770 MAX
Options Available
Allen Bradley control system
Multi-Media filters
Clean-in-Place (CIP) units
Chemical feed systems
Documentation Included
Operation and maintenance manual
Control narrative
Drawings: piping and instrumentation, electri-
cal and general dimensional
Operating Parameters
Recovery .............................................................................. 35%
Design temp. ....................................................... 77ºF (25ºC)
Design Feed TDS. .................................. 45,000 ppm NaCl
Operating range ................... 35 to 85ºF (1.6 to 29.4ºC)
Minimal inlet pressure ................................. 30 psi (2 Bar)
Materials of Construction
High-pressure piping .................. Sch. 10, Duplex 2205
Stainless Steel
Low-pressure piping ...................................... Sch. 80, PVC
Frame .................................................. Painted carbon steel
Local Enclosure ............................................ FRP, NEMA 4X