Maximum feed water specifications, E-cell stacks – GE P&W Electrodeionization (EDI) - E-Cell-3X HH Stack User Manual
Page 2

Page 2
FSelE-Cell-3XHHStack_EN
Maximum Feed Water Specifications
Feed Water - Total Exchangea-
ble Anions (TEA as CaCO
3
)
<25 mg/l
<25 ppm
Feed Water – Conductivity,
NaHCO
3
equivalent
< 43 μS/cm < 43 μS/cm
Temperature
5–40˚C
40–104˚F
Total Hardness (as CaCO
3
)
< 2.5 mg/l
< 2.5 ppm
Silica (SiO
2
)
< 1.0 mg/l
< 1.0 ppm
Total Organic Carbon (TOC as C) < 0.5 mg/l
< 0.5 ppm
Total Chlorine
< 0.05 mg/l
< 0.05 ppm
E-Cell Stacks
Product
Description
Application
Nominal
Flow
Flow Range
Resistivity
Nominal
Recovery
Hardness
E-Cell-3X
Industrial
22 gpm
5.0 m
3
/hr
10 – 28 gpm
2.3 to 6.4 m
3
/hr
> 16 MOhm-cm
87-95%
< 1.0 ppm
E-Cell-3XHH
High Hardness Industrial
22 gpm
5.0 m
3
/hr
10 – 28 gpm
2.3 to 6.4 m
3
/hr
> 16 MOhm-cm
80-95%
< 2.5 ppm
E-Cell MK-3
Industrial
15 gpm
3.4 m
3
/hr
7.5 – 20 gpm
1.7 to 4.5 m
3
/hr
> 16 MOhm-cm
87-95%
< 1.0 ppm
E-Cell MK-3Pharm
Pharmaceutical
15 gpm
3.4 m
3
/hr
7.5 – 20 gpm
1.7 to 4.5 m
3
/hr
> 10 MOhm-cm
87-95%
< 1.0 ppm
E-Cell MK-3PharmHT
Pharmaceutical
Hot water Sanitizable
15 gpm
3.4 m
3
/hr
7.5 – 20 gpm
1.7 to 4.5 m
3
/hr
> 10 MOhm-cm
87-95%
< 1.0 ppm
E-Cell MK-3Mini
Industrial
Pharmaceutical
5 gpm
1.1 m
3
/hr
2.5 to 6.5 gpm
0.6 to 1.5 m
3
/hr
> 16 MOhm-cm
78-93%
< 1.0 ppm
E-Cell MK-3MiniHT
Industrial / Pharm
Hot water Sanitizable
5 gpm
1.1 m
3
/hr
2.5 to 6.5 gpm
0.6 to 1.5 m
3
/hr
> 10 MOhm-cm
78-93%
< 1.0 ppm
MK-2 Generation stacks are only provided as replacement stacks to support existing system installations.
E-Cell MK-2E
Industrial
15 gpm
3.4 m
3
/hr
7.5 – 20 gpm
1.7 to 4.5 m
3
/hr
> 16 MOhm-cm
90-95%
< 0.5 ppm
E-Cell MK-2Pharm
Pharmaceutical
18 gpm
4.1 m
3
/hr
7.5 – 20 gpm
1.7 to 4.5 m
3
/hr
> 10 MOhm-cm
90-95%
< 0.5 ppm
E-Cell MK-2PharmHT
Pharmaceutical
Hot water Sanitizable
18 gpm
4.1 m
3
/hr
7.5 – 20 gpm
1.7 to 4.5 m
3
/hr
> 10 MOhm-cm
90-95%
< 0.5 ppm
E-Cell MK-2Mini
Industrial
Pharmaceutical
5 gpm
1.1 m
3
/hr
2.5 to 6.5 gpm
0.6 to 1.5 m
3
/hr
> 16 MOhm-cm
90-95%
< 0.5 ppm
E-Cell MK-2MiniHT
Industrial / Pharm
Hot water Sanitizable
5 gpm
1.1 m
3
/hr
2.5 to 6.5 gpm
0.6 to 1.5 m
3
/hr
> 10 MOhm-cm
90-95%
< 0.5 ppm
Other stack details can be found on the stack specific Fact Sheets.