beautypg.com

GE P&W Electrodeionization (EDI) - E-Cell-3X Stack User Manual

E-cell-3x stack, Industrial electrodeionization (edi) stacks, Description and use

background image

Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us” .

* Trademark of General Electric Company; may be registered in one or more countries.

©2011, General Electric Company. All rights reserved.

FSelE-Cell-3XStack_EN.doc Aug-11

Fact Sheet

E-Cell-3X Stack

Industrial Electrodeionization (EDI) Stacks

E-Cell*-3X is designed to:

Provide

Ultrapure

Water for industrial
applications includ-
ing Power, Semicon-
ductor, and General
Industry.

Produce Mixed Bed
quality water on a
continuous basis.

Require no caustic or acid for regeneration of
ion exchange resin within the stack.

Be leak free, guaranteed.

Eliminate brine injection and concentrate recir-
culation, simplifying system design.

Description and Use

E-Cell-3X stacks are electrodeionization (EDI)
stacks which use electrical current to deionize and
polish reverse osmosis (RO) permeate water. The
product water for the E-Cell-3X is at an Ultrapure
level required in today’s demanding applications.

Typical Applications

Microelectronics

Power Generation (NOx, Boiler Feed)

General Industry

Quality Assurance

CE, UL & CSA marked

Manufactured in a ISO 9001:2000 facility

E-Cell-3X Stack Specifications

Nominal Flow

5.0 m

3

/hr

22.0 gpm

Flow Rate Range

2.27 – 6.36 m

3

/hr

10 – 28 gpm

Shipping Weight

135 kg

298 lbs

Dimensions

(width x height x depth)

31cm x 61cm x 66cm

12’’ x 24” x 26”

Typical Performance

Product Quality

Resistivity

> 16 MOhm-cm

Sodium

< 3 ppb

Silica (SiO2) Removal

Up to 99% or < 5 ppb

Boron Removal

> 95%

Operating Parameters

Recovery

Up to 95%

Concentrate Flow

Counter current to
Product Flow

1

Voltage

0–400 VDC

Amperage

0–5.2 ADC

Inlet Pressure at Nominal Flow

4.1–6.9 bar 60–100 psi

Pressure Drop at Nominal Flow

1.4–2.8 bar 20–40 psi

Maximum Feed Water Specifications

Feed Water - Total Exchangea-
ble Anions (TEA as CaCO

3

)

<25 mg/l

<25 ppm

Feed Water – Conductivity,
NaHCO

3

equivalent

< 43 μS/cm < 43 μS/cm

Temperature

5–40˚C

40–104˚F

Total Hardness (as CaCO

3

)

< 1.0 mg/l

< 1.0 ppm

Silica (SiO

2

)

< 1.0 mg/l

< 1.0 ppm

Total Organic Carbon (TOC as C) < 0.5 mg/l

< 0.5 ppm

Total Chlorine

< 0.05 mg/l < 0.05 ppm

Actual performance may vary depending on site conditions.
Reference E-Calc projection software to verify actual performance.
Patents pending.

1

Co-flow operation is acceptable when feed hardness

concentrations are <0.1 ppm as CaCO

3.