GE P&W Spiral Wound Membranes - AE HR Series User Manual
Ae hr series, High rejection low energy seawater ro elements, Fact sheet
Fact Sheet
AE HR Series
High Rejection Low Energy Seawater RO Elements
The AE HR series of proprietary thin film reverse
osmosis membrane elements are characterized by
an excellent sodium chloride rejection. AE HR series
is selected when high quality permeate is
demanded from seawater that is relatively high in
TDS.
AE HR series new membrane chemistry provides
excellent rejection characteristics when operated at
seawater operating conditions (pressures exceed-
ing 800psi (5,516kPa).
Table 1: Element Specification
Model
Average
permeate
flow gpd
(m3/day)
1,2
Average
NaCl
rejection
1,2
Minimum
NaCl
rejection
1,2
Minimum
Boron
Rejection
2
AE-90
2000 (7.6)
99.8%
99.3%
90.0%
AE-400, 34
9000 (34.1)
99.8%
99.3%
90.0%
AE-440
9900 (37.5)
99.8%
99.3%
90.0%
1
Average salt rejection after 24 hours operation. Individual flow rate may vary
+25%/-15%.
2
Testing conditions: 32,000mg/l NaCl & 5mg/l Boron solution at 800psi (5,516kPa)
operating pressure, 77°F (25°C), pH 8.0 and 10% recovery.
Model
Active area
ft
2
(m
2
)
Outer wrap
Part
number
AE-90
90 (8.4)
Fiberglass
3056660
AE-400, 34
400 (37.2)
Fiberglass
3056662
AE-440
440 (40.9)
Fiberglass
3056663
Figure 1a: Element Dimensions Diagram – Male
Figure 1b: Element Dimensions Diagram – Female
Table 2: Operating and CIP parameters
3
SDI is measured on a non-linear scale using a 0.45 micron filter paper.
Additionally, finer colloids, particulates and microorganisms that pass
through the filter paper and not measured in the SDI test, will potential-
ly foul the RO element. For performance consistency and project war-
ranty, please use Winflows projection software and consult your Filters
with Membranes representative.
Table 3: Dimensions and Weights
Model
1
Type
Dimensions, inches (cm)
Boxed
A
B
2
C
Weight
lbs (kg)
AE-90
Male 40.0 (101.6) 0.75 (1.90)
3.9 (9.9)
9 (4)
AE-400, 34 Female 40.0 (101.6) 1.125 (2.86) 7.9 (20.1) 35 (16)
AE-440
Female 40.0 (101.6) 1.125 (2.86) 7.9 (20.1) 35 (16)
Membrane
Thin-film membrane (TFM*)
Typical Operating Pressure
800psi (5,516kPa)
Typical Operating Flux
7-11GFD (12-19LMH)
Maximum Operating Pressure 1,200psi (8,274kPa)
Maximum Temperature
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
pH range
Optimum rejection pH: 7.0-7.5,
Continuous operation: 4.0-11.0,
Clean-In-Place (CIP): 2.0-11.5
Maximum Pressure Drop
Over an element: 12 psi (83 kPa)
Per housing: 50 psi (345 kPa)
Chlorine Tolerance
1,000+ ppm-hours,
dechlorination recommended
Feedwater
3
NTU < 1
SDI < 5
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2014, General Electric Company. All rights reserved.
FSsmAEHRSeries_EN Jan-14