Table 2: Dimensions
Page 2
FS1080EN
Integrity Testing
Air diffusion per 10" module after saturation
with clean water. <12 cc/min at 40 psig (2.76 bar)
Table 3: Operational Limits
Additional Information
• Memtrex MP-S filters may be autoclaved or in
situ steam sterilized (up to 257°F [125°C],
30-minute cycles) for a maximum accumulated
exposure of 10 hours. Alternately, the
filters may be sanitized with compatible chemi-
cal agents.
• GE certifies that the material contained in its
Memtrex MP-S pleated filters meet U.S. FDA
requirements for food contact under the appli-
cable regulations in 21 CFR. For further informa-
tion, contact GE technical services. Memtrex
MP-S filters meet the test criteria for USP class
VI-121°C Plastics.
• Aqueous extracts from Memtrex MP-S filters
contain less that 0.25 EU/ml. The filters typically
exhibit low levels of non-volatile residues.
• GE filter cartridges are designed and manufac-
tured for resistance to a wide range of chemical
solutions. Conditions will vary with each appli-
cation and users should carefully verify chemi-
cal compatibility. Please contact your GE
distributor for more information.
• Table 5 provides additional ordering information.