beautypg.com

Table 2: dimensions and weight, Table 3: operating and cip parameters – GE P&W Spiral Wound Membranes - OSMO BEV ULE Reverse Osmosis User Manual

Page 2

background image

Page 2

FSsmOsmoBEVULE_EN

Table 2: Dimensions and Weight

Model

1

Dimensions, inches (cm)

Boxed

A

B

2

C

3

Weight

lbs (kg)

OSMO-BEV-ULE-CG-WT

40.0

(101.6)

1.125

(2.86)

7.9

(20.1)

35

(16)

1

These elements are bagged dried, unless specified wet (WT), before shipping.

2

Internal diameter unless specified OD (outside diameter).

3

The element diameter (dimension C) is designed for optimum performance in

GE’s pressure vessels. Others pressure vessel dimension and tolerance may result
in excessive bypass and loss of capacity.

Table 3: Operating and CIP parameters

Typical Operating
Pressure

OSMO BEV ULE: 50-100 psig (345-690 kPa)

1

Typical Operating
Temperature

105 to 50°F (41 to 10°C)

Typical Operating
Flux

13-23 GFD (22-39 LMH)

Maximum Operating

Pressure

OSMO BEV RO LE: 250 psi (1724 kPa)

1

Maximum Tempera-
ture

Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)

Minimum Crossflow

30gpm (6.8 m3/hr)

pH Range

Continuous operation: 4.0-11.0,
Clean-In-Place (CIP): 2.0-11.5

Maximum Pressure

Drop

Over an element: 12 psi (83 kPa)

Per housing: 50 psi (345 kPa)

Chlorine Tolerance

1,000+ ppm-hours,
dechlorination recommended

Feedwater

NTU < 1
SDI < 5

1

OSMO BEV ULE CAGED WET elements on 50-70°F (10-21° C) water temperature