Table 2: dimensions and weight, Table 3: operating and cip parameters – GE P&W Spiral Wound Membranes - OSMO BEV ULE Reverse Osmosis User Manual
Page 2

Page 2
FSsmOsmoBEVULE_EN
Table 2: Dimensions and Weight
Model
1
Dimensions, inches (cm)
Boxed
A
B
2
C
3
Weight
lbs (kg)
OSMO-BEV-ULE-CG-WT
40.0
(101.6)
1.125
(2.86)
7.9
(20.1)
35
(16)
1
These elements are bagged dried, unless specified wet (WT), before shipping.
2
Internal diameter unless specified OD (outside diameter).
3
The element diameter (dimension C) is designed for optimum performance in
GE’s pressure vessels. Others pressure vessel dimension and tolerance may result
in excessive bypass and loss of capacity.
Table 3: Operating and CIP parameters
Typical Operating
Pressure
OSMO BEV ULE: 50-100 psig (345-690 kPa)
1
Typical Operating
Temperature
105 to 50°F (41 to 10°C)
Typical Operating
Flux
13-23 GFD (22-39 LMH)
Maximum Operating
Pressure
OSMO BEV RO LE: 250 psi (1724 kPa)
1
Maximum Tempera-
ture
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
Minimum Crossflow
30gpm (6.8 m3/hr)
pH Range
Continuous operation: 4.0-11.0,
Clean-In-Place (CIP): 2.0-11.5
Maximum Pressure
Drop
Over an element: 12 psi (83 kPa)
Per housing: 50 psi (345 kPa)
Chlorine Tolerance
1,000+ ppm-hours,
dechlorination recommended
Feedwater
NTU < 1
SDI < 5
1
OSMO BEV ULE CAGED WET elements on 50-70°F (10-21° C) water temperature