Additional information – GE P&W Pleated Filters - Flotrex HR Pleated Filters User Manual
Page 2

Page 2
FS1091EN Jul-08
Table 2: Dimensions
Nominal O.D.
Nominal I.D.
Effective Filtration Area
2.75” (70 mm)
1.25” (31 mm)
8.0 ft
2
(0.74 m
2
)
Table 3: Operational Limits
Description
Operational Limits
Maximum Forward Differential
Pressure
60 psi (4.1 bar) at 70ºF (21ºC)
Maximum Reverse Differential
Pressure
30 psi (2.1 bar) at 70ºF (21ºC)
Maximum Operating Temperature
180ºF (82ºC) at 10 psid (0.69 bar) in
water
Table 4: Flow Performance in Clean Water
1
1
Data based on 10” length filter
Additional Information
• Flotrex-HR filters may be sanitized with com-
patible chemical agents such as ozonated
water. The filters must not be autoclaved or
steam sterilized.
• Flotrex-HR filters meet the test criteria for
USP24 class VI-121°C plastics and pass the
MEM Elution Cytotoxicity Test.
• Aqueous extracts from Flotrex-HR filters con-
tains less than 0.25 EU/ml. The filters typically
exhibit low levels of non-volatile residues. FHR
filters are ozone tolerant for 9,000 ppm/hr with
no extractables.
• Table 5 provides more information on ordering
Flotrex HR filters.
10 µm
25 µm
Table 5: Ordering Information
Type
Absolute
Micron Rating
Nominal
Cartridge Length
End #1
Adapter
End #2
Adapter
Elastomer
Material
FHR
03 = 3.0 µm
1 = 10 in (25 cm)
A = Open End Gasket
A = Open End Gasket
V = Viton
2
10 = 10 µm
4
2 = 20 in (51 cm)
E = 222 O-Ring
G = Closed End Cap
T = Teflon
2
25 = 25 µm
3 = 30 in (76 cm)
F = 226 O-Ring
H = Fin Adapter
Encapsulated Viton
4 = 40 in (102 cm)
2
Viton and Teflon are registered trademarks of DuPont.