beautypg.com

GE P&W Spiral Wound Membranes - PT Series User Manual

Pt series, Fact sheet

background image

Find a contact near you by visiting www.gewater.com/water and clicking on “Contact Us” .

* Trademark of General Electric Company; may be registered in one or more countries.

©2013, General Electric Company. All rights reserved.

AM-FSpwPTSeries_EN Nov-13

Fact Sheet

PT Series

Industrial Ultrafiltration Elements – PES 5,000 MWCO

The PT family of polyethersulfone ultrafiltration
membrane elements is characterized by a 5,000
molecular weight cut-off.

Table 1: Element Specification

Membrane

P-Series, Polyethersulfone

Model

Spacer

mil (mm)

Active area

ft

2

(m

2

)

Outer wrap

Part

number

PT8040C50

50 (1.27)

255 (23.7)

Cage

1240574

PT8040F30

30 (0.76)

350 (32.5)

Fiberglass

1229772

Figure 1: Element Dimensions Diagram (Female)

Table 2: Dimensions and Weight

Model

1

Dimensions, inches (cm)

Boxed

A

B

2

C

3

Weight

lbs (kg)

PT8040

40.0

(101.6)

1.125

(2.86)

7.9

(20.1)

29

(13.2)

1

These elements are bagged dry before shipping.

2

Internal diameter unless specified OD (outside diameter).

3

The element diameter (dimension C) is designed for optimum performance in GE

Water & Process Technologies pressure vessels. Other pressure vessel dimension
and tolerance may result in excessive bypass and loss of capacity.

Table 3: Operating and CIP parameters

Typical Operating Flux

5 – 20 GFD (8 – 34 LMH)

Maximum Operating Pressure

200psi (1,379kPa)

Maximum Temperature

Continuous Operation: 122°F (50°C)
Clean-In-Place (CIP): 122°C (50°C)

pH range

Continuous Operation: 2.0-10.0,
Clean-In-Place (CIP): 1.0-11.5

Maximum Pressure Drop

Over an element: 15psi (103kPa)
Per housing: 60psi (414kPa)

Chlorine Tolerance

5,000 ppm days