General Properties
Typical Applications
Process ingredient water
Rinse water
Food ingredient water
Safe drinking water
Boiler feed water
Ion exchange pre-treatment
Standard Economy Features (ECN)
1-micron pre-filter
Automatic inlet shut-off valve
Permeate and Concentrate flow meters
Remote machine on/off capability
Thermal Motor Protection
Pre-filter, post-filter, primary, and final pressure
gauges
Flow control center including concentrate and
recycle valves
Deluxe (DLX) Features – in addition to ECN
features
Autoflush system
Low inlet pressure switch
Digital conductivity meter with programmable relay
Alarms: Low Inlet Pressure, Motor Starter overload
Table 1: Operating Parameters
Operating Pressure
15 bar (220 psig)
Maximum Recovery
75%
Nominal Rejection
95-98%
Operating Temperature
13-30
C (55-85
F)
Minimum Inlet Pressure
2 bar (30 psig)
Design Temperature
25
C (77
F)