GE P&W Spiral Wound Membranes - CD Series User Manual
Cd series, Fact sheet, Table 1: element specification

Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
FS1264EN.doc Nov-13
CD Series
High Rejection Brackish Water RO Elements (Cellulose Acetate)
The C-Series family, a triacetate/diacetate blend,
has a higher flux and better mechanical stability
than standard cellulose acetate. C-Series elements
offer an increased chlorine resistance compared to
thin-film elements.
CD High Rejection Elements are used for brackish
water desalination and process stream.
Table 1: Element Specification
Membrane
C-Series, cellulose acetate
Model
Average
permeate flow
gpd (m3/day)
1,2
Average NaCl
rejection
1,2
Minimum NaCl
rejection
1,2
CD4025T
1,000 (3.8)
98.5%
96.5%
CD8040F
6,000 (22.7)
98.5%
96.5%
1
Average salt rejection after 24 hours operation. Individual flow rate may vary
+25%/-15%.
² Testing conditions: 2,000ppm NaCl solution at 425psi (2,930kPa) operating
pressure, 77°F, pH 6.5 and 15% recovery.
Model
Active area
ft
2
(m
2
)
Outer wrap
Part
number
CD4025T
55 (5.1)
Tape
1206834
CD8040F
390 (36.2)
Fiberglass
1206837
Figure 1: Element Dimensions Diagram - Female
Table 2: Dimensions and Weight
Model²
Dimensions, inches (cm)
Boxed
A
B
1
C
3
Weight
lbs (kg)
CD4025T
25.0
(63.5)
0.625
(1.59)
3.9
(9.9)
5
(2.3)
CD8040F
40.0
(101.6)
1.125
(2.86)
7.9
(20.1)
32
(14.5)
1
Internal diameter.
² These elements are dried then bagged before shipping.
3
The element diameter (dimension C) is designed for optimum performance in GE
pressure vessels. Others pressure vessel dimension and tolerance may result in
excessive bypass and loss of capacity.
Table 3: Operating and CIP parameters
Typical Operating Pressure
140 - 400psi (965-2,758kPa)
Typical Operating Flux
10-18 GFD (17-30 LMH)
Maximum Operating Pressure
450psi (3,103kPa)
Maximum Temperature
Continuous Operation: 86°F (30°C)
Clean-In-Place (CIP): 86°F (30°C
pH Range
Continuous Operation: 5.0-6.5,
Clean-In-Place (CIP): 3.0-8.0
Maximum Pressure Drop
Over an element: 12psi (83kPa)
Per housing: 50psi (345kPa)
Chlorine Tolerance
1ppm maximum continuous
30ppm for 30 min. during sanitization
Feedwater
NTU < 1
SDI < 5