beautypg.com

GE P&W Spiral Wound Membranes - CD Series User Manual

Cd series, Fact sheet, Table 1: element specification

background image

Fact Sheet

Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.

* Trademark of General Electric Company; may be registered in one or more countries.

©2013, General Electric Company. All rights reserved.

FS1264EN.doc Nov-13



CD Series

High Rejection Brackish Water RO Elements (Cellulose Acetate)

The C-Series family, a triacetate/diacetate blend,
has a higher flux and better mechanical stability
than standard cellulose acetate. C-Series elements
offer an increased chlorine resistance compared to
thin-film elements.
CD High Rejection Elements are used for brackish
water desalination and process stream.

Table 1: Element Specification

Membrane

C-Series, cellulose acetate

Model

Average

permeate flow

gpd (m3/day)

1,2

Average NaCl

rejection

1,2

Minimum NaCl

rejection

1,2

CD4025T

1,000 (3.8)

98.5%

96.5%

CD8040F

6,000 (22.7)

98.5%

96.5%

1

Average salt rejection after 24 hours operation. Individual flow rate may vary

+25%/-15%.

² Testing conditions: 2,000ppm NaCl solution at 425psi (2,930kPa) operating
pressure, 77°F, pH 6.5 and 15% recovery.

Model

Active area

ft

2

(m

2

)

Outer wrap

Part

number

CD4025T

55 (5.1)

Tape

1206834

CD8040F

390 (36.2)

Fiberglass

1206837

Figure 1: Element Dimensions Diagram - Female

Table 2: Dimensions and Weight

Model²

Dimensions, inches (cm)

Boxed

A

B

1

C

3

Weight

lbs (kg)

CD4025T

25.0

(63.5)

0.625

(1.59)

3.9

(9.9)

5

(2.3)

CD8040F

40.0

(101.6)

1.125

(2.86)

7.9

(20.1)

32

(14.5)

1

Internal diameter.

² These elements are dried then bagged before shipping.

3

The element diameter (dimension C) is designed for optimum performance in GE

pressure vessels. Others pressure vessel dimension and tolerance may result in
excessive bypass and loss of capacity.

Table 3: Operating and CIP parameters

Typical Operating Pressure

140 - 400psi (965-2,758kPa)

Typical Operating Flux

10-18 GFD (17-30 LMH)

Maximum Operating Pressure

450psi (3,103kPa)

Maximum Temperature

Continuous Operation: 86°F (30°C)
Clean-In-Place (CIP): 86°F (30°C

pH Range

Continuous Operation: 5.0-6.5,
Clean-In-Place (CIP): 3.0-8.0

Maximum Pressure Drop

Over an element: 12psi (83kPa)
Per housing: 50psi (345kPa)

Chlorine Tolerance

1ppm maximum continuous
30ppm for 30 min. during sanitization

Feedwater

NTU < 1
SDI < 5