GE P&W SeaPRO Series 60 Hz 35,000 ppm NaCl 20-60 gpm User Manual
Seapro series 60 hz, Basic features (bas), Premium features (pre)
![background image](/manuals/286455/1/background.png)
Fact Sheet
Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us” .
* Trademark of General Electric Company; may be registered in one or more countries.
©2009, General Electric Company. All rights reserved.
pfe1020en.doc Aug-09
SeaPRO Series 60 Hz
Seawater Desalination Machines 35,000 ppm NaCl
20-60 gpm (4.5-13.6 m
3
/hr)
Basic Features (BAS)
• GE Fanuc Quick Panel 6-inch, 6-inch color display,
Primarily text operating screens, Touchscreen con-
trols
• GE Fanuc Micro VersaMax Communication:
RS232/DH485, Analog output: 6 points
• 4-20 mA instruments displayed on instrument cen-
ter
• Variable frequency drive (VFD) for high pressure
pump
• Stand alone master control enclosure, skid
mounted local control enclosure with terminal
strips
Premium Features (PRE)
• GE Fanuc QuickPanel 12-inch, 12-inch color dis-
play, Text and pictorial operating screens, Touch-
screen controls
• GE Fanuc VersaMax Communication:
RS232/DH485/Ethernet, Analog output: 4 points
• 4-20 mA instruments on PanelView
• Primary and final pressure transmitters
•
Variable frequency drive (VFD) for high pressure
pump
• Automated valves and control for full permeate
flush upon shut down
• Stand alone master control enclosure, skid
mounted local control enclosure with remote I/O
Instrumentation
Flow Meters........................................... Permeate, concentrate
Conductivity...................................................................... Permeate
pH .....................................................................................................Feed
Pressure...................................... Pre-filter, post-filter, primary,
final, permeate, concentrate,
pump discharge (PRE Feature=
Primary, Final transmitter)
Pressure Switch.......................Feed, permeate, concentrate
Instrument center........................................Thornton 770 MAX
Options Available
• Allen Bradley control system
• Multi-Media filters
• Clean-in-Place (CIP) units
• Chemical feed systems
Documentation Included
• Operation and maintenance manual
• Control narrative
• Drawings: piping and instrumentation, electrical
and general dimensional
Operating Parameters
Recovery .............................................................................. 40 - 45%
Design temp...................................................................77ºF (25ºC)
Design Feed TDS. ............................................35,000 ppm NaCl
Operating range.............................. 35 to 85ºF (1.6 to 29.4ºC)
Minimal inlet pressure ........................................... 30 psi (2 Bar)
Materials of Construction
High-pressure piping ............................ Sch. 10, Duplex 2205
Stainless Steel
Low-pressure piping ............................................... Sch. 80, PVC
Frame ............................................................Painted carbon steel
Local Enclosure.......................................................FRP, NEMA 4X
Main Enclosure.......................Painted carbon steel, NEMA 4
VFD Enclosure ........................Painted carbon steel, NEMA 4
Clamps/fittings............................................................. Zinc-plated