beautypg.com

GE P&W SeaPRO Series 60 Hz 35,000 ppm NaCl 20-60 gpm User Manual

Seapro series 60 hz, Basic features (bas), Premium features (pre)

background image

Fact Sheet

Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us” .

* Trademark of General Electric Company; may be registered in one or more countries.

©2009, General Electric Company. All rights reserved.

pfe1020en.doc Aug-09

SeaPRO Series 60 Hz

Seawater Desalination Machines 35,000 ppm NaCl

20-60 gpm (4.5-13.6 m

3

/hr)

Basic Features (BAS)

• GE Fanuc Quick Panel 6-inch, 6-inch color display,

Primarily text operating screens, Touchscreen con-

trols

• GE Fanuc Micro VersaMax Communication:

RS232/DH485, Analog output: 6 points

• 4-20 mA instruments displayed on instrument cen-

ter

• Variable frequency drive (VFD) for high pressure

pump

• Stand alone master control enclosure, skid

mounted local control enclosure with terminal

strips

Premium Features (PRE)

• GE Fanuc QuickPanel 12-inch, 12-inch color dis-

play, Text and pictorial operating screens, Touch-

screen controls

• GE Fanuc VersaMax Communication:

RS232/DH485/Ethernet, Analog output: 4 points

• 4-20 mA instruments on PanelView
• Primary and final pressure transmitters

Variable frequency drive (VFD) for high pressure

pump

• Automated valves and control for full permeate

flush upon shut down

• Stand alone master control enclosure, skid

mounted local control enclosure with remote I/O

Instrumentation

Flow Meters........................................... Permeate, concentrate

Conductivity...................................................................... Permeate

pH .....................................................................................................Feed

Pressure...................................... Pre-filter, post-filter, primary,

final, permeate, concentrate,

pump discharge (PRE Feature=

Primary, Final transmitter)

Pressure Switch.......................Feed, permeate, concentrate

Instrument center........................................Thornton 770 MAX

Options Available

• Allen Bradley control system

• Multi-Media filters
• Clean-in-Place (CIP) units
• Chemical feed systems

Documentation Included

• Operation and maintenance manual
• Control narrative

• Drawings: piping and instrumentation, electrical

and general dimensional

Operating Parameters

Recovery .............................................................................. 40 - 45%

Design temp...................................................................77ºF (25ºC)

Design Feed TDS. ............................................35,000 ppm NaCl

Operating range.............................. 35 to 85ºF (1.6 to 29.4ºC)

Minimal inlet pressure ........................................... 30 psi (2 Bar)

Materials of Construction

High-pressure piping ............................ Sch. 10, Duplex 2205

Stainless Steel

Low-pressure piping ............................................... Sch. 80, PVC

Frame ............................................................Painted carbon steel

Local Enclosure.......................................................FRP, NEMA 4X

Main Enclosure.......................Painted carbon steel, NEMA 4

VFD Enclosure ........................Painted carbon steel, NEMA 4

Clamps/fittings............................................................. Zinc-plated

Table of contents