AD LE Series
High Rejection High Flow Seawater RO Elements
The AD LE Series, family of proprietary thin film re-
verse osmosis membrane elements, is character-
ized by an excellent sodium chloride rejection. AD
LE series is selected when high quality permeate is
demanded from seawater that is relatively high in
TDS.
AD LE Series new membrane chemistry provides
excellent rejection characteristics when operated at
seawater operating conditions (pressures exceed-
ing 800psi (5,516kPa) and elevated seawater tem-
peratures.
Table 1: Element Specification
Model
Average
permeate
flow gpd
(m3/day)
1,2
Average
NaCl
rejection
1,2
Minimum
NaCl
rejection
1,2
Minimum
Boron
rejection
2
AD-400 LE
7500 (28.4)
99.75%
99.3%
91.0%
AD-440 LE
8200 (31.0)
99.75%
99.3%
91.0%
1
Average salt rejection after 24 hours operation. Individual flow rate
may vary +25%/-15%.
2
Testing conditions: 32,000mg/l NaCl & 5mg/l Boron solution at 800psi
(5,516kPa) operating pressure, 77°F (25°C), pH 8.0 and 7% recovery.
Model
Active area
ft
2
(m
2
)
Outer wrap
Part
number
AD-400 LE
400 (37.2)
Fiberglass
3056658
AD-440 LE
440 (40.9)
Fiberglass
3056659
Table 2: Operating and CIP parameters
3
SDI is measured on a non-linear scale using a 0.45 micron filter paper.
Additionally, finer colloids, particulates and microorganisms that pass
through the filter paper and not measured in the SDI test, will potential-
ly foul the RO element. For performance consistency and project war-
ranty, please use Winflows projection software and consult your Filters
with Membranes representative.
Figure 1: Element Dimensions Diagram – Female
Table 3: Dimensions and Weights
Model
1
Type
Dimensions, inches (cm)
Boxed
A
B
2
C
Weight
lbs (kg)
AD-400 LE Female 40.0 (101.6) 1.125 (2.86)
7.9 (20.1) 35 (16)
AD-440 LE Female 40.0 (101.6) 1.125 (2.86)
7.9 (20.1) 35 (16)
Membrane
Thin-film membrane (TFM*)
Typical Operating Pressure
800psi (5,516kPa)
Typical Operating Flux
7-11GFD (12-19LMH)
Maximum Operating Pressure 1,200psi (8,274kPa)
Maximum Temperature
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
pH range
Optimum rejection: 7.0-7.5,
Continuous operation 4.0-11.0,
Clean-In-Place (CIP): 2.0-11.5
Maximum Pressure Drop
Over an element: 12 psi (83 kPa)
Per housing: 50 psi (345 kPa)
Chlorine Tolerance
1,000+ ppm-hours,
dechlorination recommended
Feedwater
3
NTU < 1
SDI < 5