beautypg.com

GE P&W Electrodeionization (EDI) - E-Cell MK-3 Stack User Manual

E-cell* mk-3 stack, Industrial electrodeionization (edi) stacks, Description and use

background image

Fact Sheet

Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us” .

* Trademark of General Electric Company; may be registered in one or more countries.

©2012, General Electric Company. All rights reserved.

FS1622EN.doc Jun-12

E-Cell* MK-3 Stack

Industrial Electrodeionization (EDI) Stacks

E-Cell* MK-3 is designed to:

Provide Ultrapure Water for industrial applica-
tions including Power, Semiconductor, and
General Industry.

Produce Mixed Bed quality water on a contin-
uous basis.

Require no caustic or acid for regeneration of
mixed bed resin within the stack.

Be leak free, guaranteed.

Eliminate brine injection and concentrate recircu-
lation, simplifying system design.

Description and Use

MK-3 E-Cell stacks are electrodeionization (EDI)
stacks which use electrical current to deionize and
polish reverse osmosis (RO) permeate water. The
product water for the MK-3 is at an Ultrapure level
required in today’s most demanding applications.

Typical Applications

Semiconductor

Microelectronics

Power Generation (NOx, Boiler Feed)

General Industry

Quality Assurance

CE, UL & CSA marked

Manufactured in a ISO 9001:2000 facility

MK-3 Stack Specifications

Nominal Flow

3.4 m

3

/hr

15.0 gpm

Flow Rate Range

1.7 – 4.5 m

3

/hr

7.5 – 20.0 gpm

Shipping Weight

92 kg

202 lbs

Dimensions

(width x height x depth)

30 cm x 61 cm x 48 cm 12” x 24” x 19”

Typical Performance

Product Quality

Resistivity

> 16 MOhm-cm

Sodium

< 3 ppb

Silica (SiO2) Removal

Up to 99% or < 5 ppb

Boron Removal

> 95%

Operating Parameters

Recovery

Up to 95%

Concentrate Flow

Counter current vs.
Product Flow

Voltage

0 – 300 VDC

Amperage

0 – 5.2 ADC

Inlet Pressure

4.1 – 6.9 bar

60 – 100 psi

Pressure Drop at Nominal Flow

1.4 – 2.4 bar

20 – 35 psi

Maximum Feed Water Specifications

Feed Water - Total Exchangea-
ble Anions (TEA as CaCO

3

)

<25 mg/l

<25 ppm

Feed Water – Conductivity,
NaHCO

3

equivalent

< 43 μS/cm

< 43 μS/cm

Temperature

4.4 – 38˚C

40 – 100˚F

Total Hardness (as CaCO

3

)

< 1.0 mg/l

< 1.0 ppm

Silica (SiO

2

)

< 1.0 mg/l

< 1.0 ppm

Total Organic Carbon (TOC as C) < 0.5 mg/l

< 0.5 ppm

Total Chlorine

< 0.05 mg/l

< 0.05 ppm

Actual performance may vary depending on site conditions.
Reference E-Calc projection software to verify actual performance.
Patents pending