beautypg.com

GE P&W Spiral Wound Membranes - AD HR Series User Manual

Ad hr series, High rejection seawater ro elements, Fact sheet

background image

Fact Sheet

AD HR Series

High Rejection Seawater RO Elements

The AD HR Series, family of proprietary thin film

reverse osmosis membrane elements, is character-

ized by an excellent sodium chloride rejection.

AD HR series is selected when high quality perme-

ate is demanded from seawater that is relatively

high in TDS.
AD HR series new membrane chemistry provides

excellent rejection characteristics when operated at

seawater operating conditions (pressures exceed-

ing 800psi (5,516kPa) and elevated seawater tem-

peratures.

Table 1: Element Specification

Membrane

Thin-film membrane (TFM*)


Model

Average

permeate

flow gpd

(m3/day)

1,2

Average

NaCl

rejection

1,2

Minimum

NaCl

rejection

1,2

Minimum

Boron

Rejection

2

AD-90

1500 (5.7)

99.75%

99.3%

93.0%

AD-365

6000 (22.7)

99.75%

99.3%

93.0%

AD-400, 34

6500 (24.6)

99.75%

99.3%

93.0%

AD-440

7100 (26.9)

99.75%

99.3%

93.0%

1

Average salt rejection after 24 hours operation. Individual flow rate

may vary +25%/-15%.

2

Testing conditions: 32,000mg/l NaCl & 5mg/l boron solution at 800psi

(5,516kPa) operating pressure, 77°F (25°C), pH 8.0 and 7% recovery.






Model

Active area

ft

2

(m

2

)

Outer wrap

Part

number

AD-90

90 (8.4)

Fiberglass

3056651

AD-365

365 (33.9)

Fiberglass

3056652

AD-400, 34

400 (37.2)

Fiberglass

3056654

AD-440

440 (40.9)

Fiberglass

3056655

Table 2: Operating and CIP parameters

3

SDI is measured on a non-linear scale using a 0.45 micron filter paper.

Additionally, finer colloids, particulates and microorganisms that pass

through the filter paper and not measured in the SDI test, will potential-

ly foul the RO element. For performance consistency and project war-

ranty, please use Winflows projection software and consult your Filters

with Membranes representative.

Typical Operating Pressure

800psi (5,516kPa)

Typical Operating Flux

7-11GFD (12-19LMH)

Maximum Operating Pressure

1,200psi (8,274kPa)

Maximum Temperature

Continuous operation: 122°F (50°C)

Clean-In-Place (CIP): 122°F (50°C)

pH range

Optimum rejection: 7.0-7.5,

Continuous operation 4.0-11.0,

Clean-In-Place (CIP): 2.0-11.5

Maximum Pressure Drop

Over an element: 12 psi (83 kPa)

Per housing: 50 psi (345 kPa)

Chlorine Tolerance

1,000+ ppm-hours,

dechlorination recommended

Feedwater

3

NTU < 1

SDI < 5

Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.

* Trademark of General Electric Company; may be registered in one or more countries.

©2014, General Electric Company. All rights reserved.

FSpsADHRSeries_EN.doc Jan-14