GE P&W E-Series Reverse Osmosis - E4H 50 Hz User Manual
E4h series 50 hz, General properties
Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
FS1131EN.doc Jul-13
E4H Series 50 Hz
Reverse Osmosis Machine 2.6-6.8 cubic meters per hour
Figure 1: E4H Series
When you mention reverse osmosis (RO), GE is the
first name to come to mind. Our E-series RO ma-
chines (Figure 1) are designed for durable operation,
high quality product water production, easy installa-
tion and straightforward control.
General Properties
Typical Applications
Process ingredient water
Safe drinking water
Boiler feed water
Ion exchange pre-treatment
Standard Economy Features
5-micron pre-filter and housing, 20-inch (50.80 cm)
Automatic inlet shutoff valve
Motor thermal protection
Pre/Post-filter and primary/final pressure gaug-
es
Permeate and concentrate flow rotameters
Permeate conductivity meter
ALARMS: Low inlet pressure, high amp draw
Feed water flush on shut down
Deluxe (DLX) Features – In addition to ECN
Features
Accutrak RO microprocessor controller
SD card for collection of operating data
Permeate and concentrate paddlewheel flow
sensors
Inlet pH sensor
Permeate tank level monitoring
Chemical dosing pump for antiscalant dosing or
pH adjustment
Clean in Place (CIP) system, 5 HP (3.7 KW)
ALARMS: Low inlet pressure, high concentrate and
permeate pressure, high temperature, high per-
meate conductivity, high/low pH, motor fault, and
fill-time exceeded
Table 1: Operating Parameters
Operating Pressure
14-15 bar
Maximum Recovery
75%
Nominal Rejection
95-98%
Operating Temperature
13-30
C (55-85
F)
Minimum Inlet Pressure
2 bar (30 psig)
Design Temperature
25
C (77
F)