beautypg.com

GE P&W E-Series Reverse Osmosis - E4H 50 Hz User Manual

E4h series 50 hz, General properties

background image

Fact Sheet

Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.

* Trademark of General Electric Company; may be registered in one or more countries.

©2013, General Electric Company. All rights reserved.

FS1131EN.doc Jul-13



E4H Series 50 Hz

Reverse Osmosis Machine 2.6-6.8 cubic meters per hour

Figure 1: E4H Series

When you mention reverse osmosis (RO), GE is the
first name to come to mind. Our E-series RO ma-
chines (Figure 1) are designed for durable operation,
high quality product water production, easy installa-
tion and straightforward control.

General Properties

Typical Applications

Process ingredient water

Safe drinking water

Boiler feed water

Ion exchange pre-treatment

Standard Economy Features

5-micron pre-filter and housing, 20-inch (50.80 cm)

Automatic inlet shutoff valve

Motor thermal protection

Pre/Post-filter and primary/final pressure gaug-
es

Permeate and concentrate flow rotameters

Permeate conductivity meter

ALARMS: Low inlet pressure, high amp draw

Feed water flush on shut down

Deluxe (DLX) Features – In addition to ECN
Features

Accutrak RO microprocessor controller

SD card for collection of operating data

Permeate and concentrate paddlewheel flow
sensors

Inlet pH sensor

Permeate tank level monitoring

Chemical dosing pump for antiscalant dosing or
pH adjustment

Clean in Place (CIP) system, 5 HP (3.7 KW)

ALARMS: Low inlet pressure, high concentrate and
permeate pressure, high temperature, high per-
meate conductivity, high/low pH, motor fault, and
fill-time exceeded

Table 1: Operating Parameters

Operating Pressure

14-15 bar

Maximum Recovery

75%

Nominal Rejection

95-98%

Operating Temperature

13-30

C (55-85

F)

Minimum Inlet Pressure

2 bar (30 psig)

Design Temperature

25

C (77

F)