GE P&W Electrodeionization (EDI) - E-Cell MK-2PharmHT User Manual
E-cell mk-2 pharmht, Description and use, Fact sheet

Find a contact near you by
visiting gewater.com or
e-mailing [email protected].
Americas
Watertown, MA
+1-617-926-2500
Europe/Middle East/Africa
Heverlee, Belgium
+32-16-40-20-00
Asia/Pacific
Shanghai, China
+86 (0) 411-8366-6489
Global Headquarters
Trevose, PA
+1-215-355-3300
©2007, General Electric Company. All rights reserved.
*Trademark of General Electric Company; may be registered in one or more countries.
PFE1003EN 0701
Fact Sheet
E-Cell MK-2 PharmHT
Heat Sanitizable Ultrapure Water for Pharmaceutical Industry
Description and Use
E-Cell* electrodeinization (EDI) technology is setting
the industry standard for chemical-free, ultra-pure
water production. E-cell stacks offer a robust alter-
native to mixed bed technology.
The PharmHT model series is designed to deliver
high purity water for pharmaceutical applications
where heat sanitization is required, rated for 60 cy-
cles of sanitization at 80°C.
The modular design allows configuration of single
or multiple stacks to provide a cost-effective treat-
ment across all flow requirements.
Parameter
US Units
SI Units
Product Water
Flow rate per stack
7.0 to 20 gpm
1.6 to 4.5 m
3
/h
Resistivity
> 10 MOhm-cm
> 10 MOhm-cm
Feed Water (RO Permeate or Equivalent)
Feed TEA (per E-calc
Projection software)
< 39 ppm as CaCO
3
*
< 39 mg/L as CaCO
3
*
Silica (SiO
2
)
< 500 ppb
< 500 ug/L
TOC
< 0.5 ppm
< 0.5 mg/L
Operational Temperature Range
40 to 100°F
4.4 to 38°C
Hardness
< 0.5 ppm
< 0.5 mg/L
*Actual performance may vary depending on site conditions. Reference E-Calc projection software to verify actual performance.
Operating Parameters
Nominal recovery
90% to 95%
90% to 95%
DC power consumption (nom.)
0.2 to 1.5 kWh/1000 US gal
0.05 to 0.4 kWh/m
3
Feed pressure
50 to 100 psig
3.4 to 6.9 bar
Pressure drop
20 to 45 psid
1.4 to 3.1 bar
Dimensions
12” W x 19” D x 24” H
30cm W x 48cm D x 61cm H
Weight 202
lb
92
kg
Heat Sanitization Parameters (RO Permeate or Equivalent)
Dilute flow rate per stack
7 to 10 gpm
1.6 to 2.3 m
3
/h
Concentrate flow rate per stack
2 to 3 gpm
450 to 680 L/h
Inlet Sanitization Temperature
< 185°F <
85°C
Feed Pressure
< 30 psig
< 2.1 bar