TS-MWTS-Mobile-EN-0107-NA GE Logo Mar-08
Standard Features:
Membrane Module
ZeeWeed 500 (NSF Certified)
Membrane Type
Reinforced, low pressure, immersed hollow fi-
ber
Permeate Flow Path
Outside-in
Nominal Pore size
0.04 microns
Membrane
Membrane material
PVDF
Configuration
1 train with 4 cassettes, 26 modules per cas-
sette
Dimensions
40’L x 8.0'W x 9.5’H (40’(12m) HC ISO Container)
12.2m L x 2.5m W x 2.9m H
Membrane tank
316 Stainless Steel
Process piping
316 Stainless Steel
MIT (membrane integrity test)
Yes
Automatic backpulse cleaning
Yes
LT2 compliance
Yes
Process tank volume
4,800 gal; 18,168 L
Clean in Place (CIP) tank volume
1,184 gal; 4,481 L
Weight, shipping/operating
55,000 / 130,000 lbs (24,950 / 58,970 kg)
Aeration scour
Blower self-contained
Control - Interface
Allen Bradley PLC with Transduction PC (HMI)
Instrumentation
Feed and permeate turbidimeters and perme-
ate particle counter
Data Collection System
ZenoTrac™
System
Technical support 24/7
Yes
Overhead clearance
12 ft (3.66 m) minimum
Surrounding access
5 ft (1.5 m) minimum
Electrical
460V/3ph/60Hz/236 amps
Raw water pressure
5 psig (34.5 kPa) minimum
20 psig (138 kPa) maximum
Requirements
Raw water screening
< 1 mm
Process Flow Diagram
Average Feed Water Characteristics
Source Parameters Permeate
Direct
Filtration
<100 NTU turbidity
<5 mg/L TOC
<0.3 NTU turbidity
Enhanced
Coagulation
<100 NTU turbidity
>5 mg/L TOC*
<0.3 NTU turbidity
Settled
Water
<5 NTU turbidity
<0.3 NTU turbidity
Oxidation
(Fe & Mn)
<10 NTU turbidity
<5 mg/L TOC
>1 mg/L Fe,*
>0.3 mg/L Mn*
<0.3 NTU turbidity
Secondary /
Tertiary
Effluent
<100 mg/L TSS
<0.3 NTU turbidity
* Operating parameters to be confirmed with GE membrane solutions under these conditions