GE P&W Electrodeionization (EDI) - E-Cell MK-3Mini Stack User Manual
E-cell* mk-3mini stack, Description and use, Typical applications
Fact Sheet
Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us” .
* Trademark of General Electric Company; may be registered in one or more countries.
©2012, General Electric Company. All rights reserved.
FS1624EN.doc Jun-12
E-Cell* MK-3Mini Stack
Electrodeionization (EDI) Stacks for Low Flow Applications
E-Cell* MK-3Mini is designed to:
Provide Ultrapure Water for industrial applica-
tions including Power, Semiconductor, and
General Industry.
Produce Mixed Bed quality water on a contin-
uous basis.
Require no caustic or acid for regeneration of
mixed bed resin within the stack.
Be leak free, guaranteed
Eliminate brine injection and concentrate recircu-
lation, simplifying system design.
Description and Use
MK-3Mini E-Cell stacks are Electrodeionization
(EDI) stacks which use electrical current to deion-
ize and polish reverse osmosis (RO) permeate wa-
ter. The product water for the MK-3Mini is at an
Ultrapure level required in today’s most demand-
ing applications.
Typical Applications
Pharmaceutical
Laboratory
Semiconductor/Microelectronics
General Industry
Quality Assurance
CE, UL & CSA marked
Manufactured in a ISO 9001:2000 facility
MK-3Mini Stack Specifications
Nominal Flow
1.14 m
3
/hr
5.0 gpm
Flow Rate Range
0.45 – 1.5 m
3
/hr
2.0 – 6.5 gpm
Shipping Weight
49 kg
107 lbs
Dimensions
(width x height x depth)
30 cm x 61 cm x 28 cm 12” x 24” x 11”
Typical Performance
Product Quality
Resistivity
> 16 MOhm-cm
Sodium
< 3 ppb
TOC (as C)
< 500 ppb
Silica (SiO2) Removal
Up to 99% or < 5 ppb
Operating Parameters
Recovery
Up to 95%
Concentrate Flow
Counter current vs.
Product Flow - Standard
Co-current vs. Product Flow –
when fed by double pass RO
Voltage
0 – 150 VDC
Amperage
0 – 5.2 ADC
Inlet Pressure
4.1 – 6.9 bar
60 – 100 psi
Pressure Drop at Nominal Flow
1.4 – 2.4 bar
20 – 35 psi
Maximum Feed Water Specifications
Feed Water - Total Exchangea-
ble Anions (TEA as CaCO
3
)
<25 mg/l
<25 ppm
Feed Water – Conductivity,
NaHCO
3
equivalent
< 43 μS/cm
< 43 μS/cm
Temperature
4.4 – 38˚C
40 – 100˚F
Total Hardness (as CaCO
3
)
< 1.0 mg/l
< 1.0 ppm
Silica (SiO
2
)
< 1.0 mg/l
< 1.0 ppm
Total Organic Carbon (TOC as C) < 0.5 mg/l
< 0.5 ppm
Total Chlorine
< 0.05 mg/l
< 0.05 ppm
Actual performance may vary depending on site conditions.
Reference E-Calc projection software to verify actual performance.
Patents pending.