beautypg.com

GE P&W SeaPRO-E-210 - 2500 m3_day (460 gpm) User Manual

Seapro* e-series, 2500 m, Day (460 gpm) seawater desalination machine

background image


Fact Sheet

Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.

* Trademark of General Electric Company; may be registered in one or more countries.

©2013, General Electric Company. All rights reserved.

FSpwSeaPRO-E-2500_EN.doc Jul-13



SeaPRO* E-Series

2500 m

3

/day (460 gpm) Seawater Desalination Machine

General Features

Major components skid-mounted for easy
installation and dependable operation

Variable frequency drive (VFD) for high pressure
pump optimal control, energy efficiency and
constant water production

Simple manual control for the system, and
Hand/Auto control for remote starting and
stopping of the system

Operating Parameters

Recovery .............................................................................. 45%
Design temp. ........................................................ 25ºC (77

F)

Operating range .............................. 15-32

C (59-90

F)

1)

Design Feed TDS ..................................................... 45k ppm
Nominal rejection ............................................................ 99%
Minimum inlet pressure .......................... 2 bar (30 PSIG)

1)

Varying the operating temperature may affect permeate rate

Materials of Construction

High-pressure piping .............. Sch 40 SS Duplex 2205
Low-pressure piping ........... Sch 80 PVC DIN PN10/16
Frame ................... Anti-corrosion treated carbon steel
Frame Finish ....... 2-coat epoxy painted & blue finish
Enclosures............................................... IP55

carbon steel

Membranes .................................................................. AD-400
Membrane Housing ..... FRP 8in-1200psi-7M (82 bar)
Cartridge Filters ................. 5-micron nominal, Hytrex*
Cartridge Filter Housing ................................................. FRP

Standard package includes energy recovery
device for operating cost savings

Flow and Conductivity 4-20mA signals available
for remote monitoring/recording

Table 1: Standard Instrumentation

Flow (magnetic)

Permeate, Concentrate

Conductivity

Permeate

Pressure Switch

Feed LP, Feed HP,

Concentrate, Permeate

Pressure Indicators

Prefilter,

Post-filter,

Pump suction,

Pump discharge,

ERD HP discharge,

ERD LP discharge,

Permeate, Concentrate

Figure 1. SeaPRO-E-105 General Layout (reference only)