AG LF Series
Low Fouling Brackish Water Reverse Osmosis Elements
The A-Series LF proprietary thin-film reverse osmo-
sis (RO) membrane elements are characterized by
high flow, high sodium chloride rejection and low
fouling surface properties. AG LF brackish water
elements are selected when high rejection and op-
erating pressures as low as 200 psi (1,379 kPa) are
desired. These elements are recommended for
brackish water with salt concentration (TDS) levels
between 1,000 and 10,000mg/l or when very high
salt rejection of monovalent ions is required.
AG LF high rejection brackish water elements fea-
ture a Fiberglass outer wrap.
Table 1: Element Specification
Membrane
Thin-film membrane (TFM*)
Model
Average
permeate
flow gpd
(m3/day)
1,2
Average NaCl
rejection
1,2
Minimum NaCl
rejection
1,2
AG4040F LF, WET
2,200 (8.33)
99.5%
99.0%
AG8040F 400 LF, WET
10,500 (39.7)
99.5%
99.0%
1
Average salt rejection after 24 hours operation. Individual flow rate may vary
+25%/-15%.
2
Testing conditions: 2,000ppm NaCl solution at 225psi (1,550kPa) operating
pressure, 77°F, pH7 and 15% recovery.
Model
Active area
ft
2
(m
2
)
Outer wrap
Part
number
AG4040F LF, WET
85 (7.9)
Fiberglass
3056468
AG8040F 400 LF, WET
400 (37.2)
Fiberglass
3056466
Figure 1: Element Dimensions Diagram - AG8040F 400 LF,
WET
Figure 2: Element Dimensions Diagram – AG4040F LF, WET
Table 2: Dimensions and Weight
Model
1
Dimensions, inches (cm)
Boxed
A
B²
C
Weight
lbs (kg)
AG4040F LF, WET
40.0
(101.6)
0.75
(1.9) OD
3.88
(9.9)
12
(5.5)
AG8040F 400 LF, WET
40.0
(101.6)
1.125
(2.86)
7.9
(20.1)
35
(16)
1
These elements are bagged wet (WT) before shipping.
² Internal diameter unless specified OD (outside diameter).
Table 3: Operating and CIP parameters
Typical Operating Pressure
200 psi (1,380 kPa)
Typical Operating Flux
10-20GFD (15-35LMH)
Maximum Operating Pressure
600 psi (4,137 kPa)
Maximum Temperature
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
pH range
Optimum rejection: 7.0-7.5,
Continuous operation 4.0-11.0,
Clean-In-Place (CIP): 2.0-11.5
Maximum Pressure Drop
Over an element: 12 psi (83 kPa)
Per housing: 50 psi (345 kPa)
Chlorine Tolerance
1,000+ ppm-hours,
dechlorination recommended
Feedwater
NTU < 1
SDI < 5