AG LF Series

Low Fouling Brackish Water Reverse Osmosis Elements

The A-Series LF proprietary thin-film reverse osmo-
sis (RO) membrane elements are characterized by
high flow, high sodium chloride rejection and low
fouling surface properties. AG LF brackish water
elements are selected when high rejection and op-
erating pressures as low as 200 psi (1,379 kPa) are
desired. These elements are recommended for
brackish water with salt concentration (TDS) levels
between 1,000 and 10,000mg/l or when very high
salt rejection of monovalent ions is required.
AG LF high rejection brackish water elements fea-
ture a Fiberglass outer wrap.

Table 1: Element Specification

Membrane

Thin-film membrane (TFM*)

Model

Average

permeate

flow gpd

(m3/day)

1,2

Average NaCl

rejection

1,2

Minimum NaCl

rejection

1,2

AG4040F LF, WET

2,200 (8.33)

99.5%

99.0%

AG8040F 400 LF, WET

10,500 (39.7)

99.5%

99.0%

1

Average salt rejection after 24 hours operation. Individual flow rate may vary

+25%/-15%.

2

Testing conditions: 2,000ppm NaCl solution at 225psi (1,550kPa) operating

pressure, 77°F, pH7 and 15% recovery.

Model

Active area

ft

2

(m

2

)

Outer wrap

Part

number

AG4040F LF, WET

85 (7.9)

Fiberglass

3056468

AG8040F 400 LF, WET

400 (37.2)

Fiberglass

3056466

Figure 1: Element Dimensions Diagram - AG8040F 400 LF,

WET

Figure 2: Element Dimensions Diagram – AG4040F LF, WET

Table 2: Dimensions and Weight

Model

1

Dimensions, inches (cm)

Boxed

A

C

Weight

lbs (kg)

AG4040F LF, WET

40.0

(101.6)

0.75

(1.9) OD

3.88

(9.9)

12

(5.5)

AG8040F 400 LF, WET

40.0

(101.6)

1.125

(2.86)

7.9

(20.1)

35

(16)

1

These elements are bagged wet (WT) before shipping.

² Internal diameter unless specified OD (outside diameter).

Table 3: Operating and CIP parameters

Typical Operating Pressure

200 psi (1,380 kPa)

Typical Operating Flux

10-20GFD (15-35LMH)

Maximum Operating Pressure

600 psi (4,137 kPa)

Maximum Temperature

Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)

pH range

Optimum rejection: 7.0-7.5,
Continuous operation 4.0-11.0,
Clean-In-Place (CIP): 2.0-11.5

Maximum Pressure Drop

Over an element: 12 psi (83 kPa)
Per housing: 50 psi (345 kPa)

Chlorine Tolerance

1,000+ ppm-hours,
dechlorination recommended

Feedwater

NTU < 1
SDI < 5