Fact Sheet

AK HR Series

High Rejection Low Energy Brackish Water RO Elements

The A-Series proprietary thin-film reverse osmosis
membrane elements are characterized by high flux
and high sodium chloride rejection. AK HR low
pressure brackish elements are selected when high
rejection and low operating pressures are desired.
These elements allow significant energy savings
since good rejection is achieved at operating pres-
sures as low as 100 psig (689 kPa).
These elements are recommended for low brackish
water with salt concentration (TDS) levels up to
5,000mg/l. In turn, AK HR elements produce a per-
meate quality close to a standard brackish mem-
brane element at a much lower pressure.

Table 1: Element Specification

1

Average salt rejection after 24 hours operation. Individual flow rate

may vary +25%/-15%.

2

Testing conditions: 500ppm NaCl solution at 115psi (793kPa) operating

pressure, 77°F (25°C), pH7.5 and 15% recovery.

Model

Active area

ft

2

(m

2

)

Outer wrap

Part

number

AK-90

90 (8.4)

Fiberglass

3056678

AK-365

365 (33.9)

Fiberglass

3056679

AK-400

400 (37.2)

Fiberglass

3056680

AK-440

440 (40.9)

Fiberglass

3056681

AK-1600

1600 (148.6)

Fiberglass

3056682

Table 2: Operating and CIP parameters

3

SDI is measured on a non-linear scale using a 0.45 micron filter paper.

Additionally, finer colloids, particulates and microorganisms that pass
through the filter paper and not measured in the SDI test, will potential-
ly foul the RO element. For performance consistency and project war-
ranty, please use Winflows projection software and consult your Filters
with Membranes representative.

Figure 1a: Element Dimensions Diagram – Male






Figure 1b: Element Dimensions Diagram – Female




Membrane

Thin-film membrane (TFM*)

Model

Average

permeate flow

gpd (m3/day)

1,2

Average

NaCl

rejection

1,2

Minimum

NaCl

rejection

1,2

AK-90

2200 (8.3)

99.5%

99.0%

AK-365

9600 (36.3)

99.5%

99.0%

AK-400

10500 (39.7)

99.5%

99.0%

AK-440

11500 (43.5)

99.5%

99.0%

AK-1600

42000 (159.0)

99.5%

99.0%

Typical Operating Pressure

120 psi (830 kPa)

Typical Operating Flux

10-20GFD (15-35LMH)

Maximum Operating Pressure 400 psi (2,758 kPa)

Maximum Temperature

Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)

pH range

Optimum rejection pH: 7.0-7.5,
Continuous operation: 4.0-11.0,
Clean-In-Place (CIP): 2.0-11.5

Maximum Pressure Drop

Over an element: 12 psi (83 kPa)
Per housing: 50 psi (345 kPa)

Chlorine Tolerance

1,000+ ppm-hours,
dechlorination recommended

Feedwater

3

NTU < 1
SDI < 5