GE P&W Spiral Wound Membranes - AK HR Series User Manual
Ak hr series, Fact sheet
Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2011, General Electric Company. All rights reserved.
FSpwAKHRSeries_EN Sep 11
Fact Sheet
AK HR Series
High Rejection Low Energy Brackish Water RO Elements
The A-Series proprietary thin-film reverse osmosis
membrane elements are characterized by high flux
and high sodium chloride rejection. AK HR low
pressure brackish elements are selected when high
rejection and low operating pressures are desired.
These elements allow significant energy savings
since good rejection is achieved at operating pres-
sures as low as 100 psig (689 kPa).
These elements are recommended for low brackish
water with salt concentration (TDS) levels up to
5,000mg/l. In turn, AK HR elements produce a per-
meate quality close to a standard brackish mem-
brane element at a much lower pressure.
Table 1: Element Specification
1
Average salt rejection after 24 hours operation. Individual flow rate
may vary +25%/-15%.
2
Testing conditions: 500ppm NaCl solution at 115psi (793kPa) operating
pressure, 77°F (25°C), pH7.5 and 15% recovery.
Model
Active area
ft
2
(m
2
)
Outer wrap
Part
number
AK-90
90 (8.4)
Fiberglass
3056678
AK-365
365 (33.9)
Fiberglass
3056679
AK-400
400 (37.2)
Fiberglass
3056680
AK-440
440 (40.9)
Fiberglass
3056681
AK-1600
1600 (148.6)
Fiberglass
3056682
Table 2: Operating and CIP parameters
3
SDI is measured on a non-linear scale using a 0.45 micron filter paper.
Additionally, finer colloids, particulates and microorganisms that pass
through the filter paper and not measured in the SDI test, will potential-
ly foul the RO element. For performance consistency and project war-
ranty, please use Winflows projection software and consult your Filters
with Membranes representative.
Figure 1a: Element Dimensions Diagram – Male
Figure 1b: Element Dimensions Diagram – Female
Membrane
Thin-film membrane (TFM*)
Model
Average
permeate flow
gpd (m3/day)
1,2
Average
NaCl
rejection
1,2
Minimum
NaCl
rejection
1,2
AK-90
2200 (8.3)
99.5%
99.0%
AK-365
9600 (36.3)
99.5%
99.0%
AK-400
10500 (39.7)
99.5%
99.0%
AK-440
11500 (43.5)
99.5%
99.0%
AK-1600
42000 (159.0)
99.5%
99.0%
Typical Operating Pressure
120 psi (830 kPa)
Typical Operating Flux
10-20GFD (15-35LMH)
Maximum Operating Pressure 400 psi (2,758 kPa)
Maximum Temperature
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
pH range
Optimum rejection pH: 7.0-7.5,
Continuous operation: 4.0-11.0,
Clean-In-Place (CIP): 2.0-11.5
Maximum Pressure Drop
Over an element: 12 psi (83 kPa)
Per housing: 50 psi (345 kPa)
Chlorine Tolerance
1,000+ ppm-hours,
dechlorination recommended
Feedwater
3
NTU < 1
SDI < 5