Figure 1: element dimensions diagram - female, Table 2: dimensions and weight, Table 3: operating and cip parameters – GE P&W Spiral Wound Membranes - OSMO BEV Reverse Osmosis Series User Manual
Page 2
![background image](/manuals/286365/2/background.png)
Page 2
FS1278EN
Figure 1: Element Dimensions Diagram - Female
Table 2: Dimensions and Weight
Model
1
Dimensions, inches (cm)
Boxed
A
B
2
C
3
Weight
lbs (kg)
OSMO-BEV-RO-FF
40.0
(101.6)
1.125
(2.86)
7.9
(20.1)
32
(14.5)
OSMO-BEV-RO-WT-FF
40.0
(101.6)
1.125
(2.86)
7.9
(20.1)
35
(16)
OSMO-BEV-RO-LE-WT-FF
40.0
(101.6)
1.125
(2.86)
7.9
(20.1)
35
(16)
1
These elements are bagged dried, unless specified wet (WT), before shipping.
2
Internal diameter unless specified OD (outside diameter).
3
The element diameter (dimension C) is designed for optimum performance in GE
Water & Process Technologies pressure vessels. Others pressure vessel dimension
and tolerance may result in excessive bypass and loss of capacity.
Table 3: Operating and CIP parameters
Typical Operating Pressure
OSMO BEV RO: 200 psi (1,379 kPa)
1
OSMO BEV RO LE: 110 psi (758kPa)
2
Typical Operating Flux
10-20GFD (15-35 LMH)
Maximum Operating Pressure
OSMO BEV RO: 600 psi (4,137 kPa)
1
OSMO BEV RO LE: 400 psi (2,758 kPa)
2
Maximum Temperature
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
Minimum Crossflow
30gpm (6.8 m3/hr)
pH Range
Continuous operation: 4.0-11.0,
Clean-In-Place (CIP): 2.0-11.5
Maximum Pressure Drop
Over an element: 12 psi (83 kPa)
Per housing: 50 psi (345 kPa)
Chlorine Tolerance
1,000+ ppm-hours,
dechlorination recommended
Feedwater
NTU < 1
SDI < 5
1
OSMO BEV RO and OSMO BEV RO WET elements
2
OSMO BEV RO LE WET elements