beautypg.com

Figure 1: element dimensions diagram - female, Table 2: dimensions and weight, Table 3: operating and cip parameters – GE P&W Spiral Wound Membranes - OSMO BEV Reverse Osmosis Series User Manual

Page 2

background image

Page 2

FS1278EN

Figure 1: Element Dimensions Diagram - Female

Table 2: Dimensions and Weight

Model

1

Dimensions, inches (cm)

Boxed

A

B

2

C

3

Weight

lbs (kg)

OSMO-BEV-RO-FF

40.0

(101.6)

1.125

(2.86)

7.9

(20.1)

32

(14.5)

OSMO-BEV-RO-WT-FF

40.0

(101.6)

1.125

(2.86)

7.9

(20.1)

35

(16)

OSMO-BEV-RO-LE-WT-FF

40.0

(101.6)

1.125

(2.86)

7.9

(20.1)

35

(16)

1

These elements are bagged dried, unless specified wet (WT), before shipping.

2

Internal diameter unless specified OD (outside diameter).

3

The element diameter (dimension C) is designed for optimum performance in GE

Water & Process Technologies pressure vessels. Others pressure vessel dimension
and tolerance may result in excessive bypass and loss of capacity.

Table 3: Operating and CIP parameters

Typical Operating Pressure

OSMO BEV RO: 200 psi (1,379 kPa)

1

OSMO BEV RO LE: 110 psi (758kPa)

2

Typical Operating Flux

10-20GFD (15-35 LMH)

Maximum Operating Pressure

OSMO BEV RO: 600 psi (4,137 kPa)

1

OSMO BEV RO LE: 400 psi (2,758 kPa)

2

Maximum Temperature

Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)

Minimum Crossflow

30gpm (6.8 m3/hr)

pH Range

Continuous operation: 4.0-11.0,
Clean-In-Place (CIP): 2.0-11.5

Maximum Pressure Drop

Over an element: 12 psi (83 kPa)
Per housing: 50 psi (345 kPa)

Chlorine Tolerance

1,000+ ppm-hours,
dechlorination recommended

Feedwater

NTU < 1
SDI < 5

1

OSMO BEV RO and OSMO BEV RO WET elements

2

OSMO BEV RO LE WET elements