5 of 10

ISSUED: 01-17-12 SHEET #: 125-9277-1

Position wall mount assembly (

A) at desired position

on wall

.

Use wall mount assembly, making sure that

it is level, as a template to mark holes. Drill four

5/16" (8mm) dia. holes to a minimum depth of 2-1/2"

(64 mm). Concrete must be 2000 psi density

minimum. Insert anchors (

E) in holes flush with wall

as shown in figure 2.4. Place wall mount assembly

over anchors and secure with #14 x 2-1/2" wood

screws (

D) as shown in figure 2.5. Make sure wall

plate is level and tighten all fasteners.

Installation to Solid Concrete and Cinder Block Wall

2

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete

thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a

solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90

specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a

hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached

hardware and components.

WARNING

D

A

fig 2.5

SOLID

CONCRETE

CINDER

BLOCK

E

1

3

2

E

Drill holes and insert anchors (

E).

Place plate (

A) over anchors (E) and secure with screws (D).

Tighten all fasteners.

A

E

D

concrete

surface

• Tighten wood screws so that wall plate is firmly at-

tached, but do not overtighten. Overtightening can

damage screws, greatly reducing their holding power.

• Never tighten in excess of 80 in • lb (9 N.M.).

WARNING

• Always attach concrete expansion anchors directly

to load-bearing concrete.

• Never attach concrete expansion anchors to con-

crete covered with plaster, drywall, or other finishing

material. If mounting to concrete surfaces covered

with a finishing surface is unavoidable, the finishing

surface must be counterbored as shown below. If

plaster/drywall is thicker than 5/8", custom fasteners

must be supplied by installer.

WARNING

CUT

AW

AY

VIEW

INCORRECT

CORRECT

wall

plate

wall

plate

plaster/

dry wall

plaster/

dry wall

concrete

concrete