Drill two 5/16" (8 mm) dia. holes to a minimum depth
of 1-3/4" (45 mm). Attach upper ceiling bracket (A)
using concrete expansion anchors (ACC 200) as
shown. Tighten to 80 in. • lb (9 N.M.) maximum
torque.
CUTAWAY VIEW
STEP 1: Hammer
in concrete anchor.
A
STEP 2: Tighten to 80 in. • lb (9 N.M.)
maximum torque to expand anchors.
Cross Section: Attachment
to a concrete ceiling.
CONCRETE ANCHOR
INSTALLATION
FOR PRODUCT SAFETY USE ONLY...
RAWL
™
#5005 OR HILTI
™
HL814
CONCRETE ANCHORS [.312 x
1.625 (8 mm x 41 mm)]. ORDER
ACCESSORY FASTENER KIT
#ACC 200
Installation to Concrete Ceiling
• Tighten concrete anchor bolts firmly, but do not
overtighten. Overtightening can damage the bolts,
greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
A
CONCRETE ANCHOR
WALL
CEILING
• Always attach concrete expansion anchors directly to
load-bearing concrete.
• Never attach concrete expansion anchors to concrete
covered with plaster, drywall or other finishing material.
WARNING