ATEX Installation Requirements

1. The conductor size of the phase conductor must be in the range of 0.05-2.08 mm2.

2. Field wiring must be suitable for a minimum of 110°C.

3. Ethernet Switches are intended for mounting in an IP54 enclosure in a pollution degree 2

environ

ment.

4. Temperature testing of the Ethernet Switches was conducted on the switch itself in an 85°C air-

circulating oven and resulted in a Temperature Code of T4. However, end-product temperature testing
shall be considered.

5. The end user shall provide bonding means as necessary. All bonding equipment (components) shall be

evaluated according to EN 60079-15:2005 and covered by a component certificate for the actual use.
When installing bonding components that will pass through an enclosure wall, they must have a
minimum of IP54 rating equal to the enclosure. All electrical clearances must be maintained per the
manufacturer‟s instructions of the bonding component or per EN 60079-15:2005.

6. Ethernet Switch requires protection against transients. The end-product shall provide a suitable form of

protection that removes the risk of or limits transients to no more than 42V.