29

Fiber Transceiver Characteristics

Fiber Length:

2km*

15km**

40km**

80km**

TX Power Min

-19dBm

-15dBm

-5dBm

-5dBm

RX Sensitivity Max:

-31dBm

-31dBm

-34dBm

-34dBm

Wavelength:

1310nm

1310nm

1310nm

1550nm

*=Multimode

** =Singlemode


Recommended Wiring Clearance:

Top: 1 " (2.54 cm)

Front: 4 " (10.16 cm)


Regulatory Approvals:
Safety:
Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations, or Nonhazardous

Locations only.

ATEX Zone 2, Category 3G, II 3G Ex nA IIC (DEMKO 03 ATEX 0316686U)


EMI:

EN61000-6-4, EN55011

– Class A

FCC 47 CFR, Part 15, Subpart B -Class A

EMS: EN61000-6-2

EN61000-4-2 (ESD)

EN61000-4-3 (RS)

EN61000-4-4 (EFT)

EN61000-4-5 (Surge)

EN61000-4-6 (Conducted Disturbances)


Conducted Low Frequency: IEC60533

Shock:

IEEE 1613 (250 mm)

Vibration:

IEEE 1613 (V.S.4 150 mm/s)

IEC60068-2-6 (Test F

c

)

Cold:

IEC60068-2-1

Dry Heat:

IEC60068-2-2

Damp Heat:

IEC60068-2-30 (Test D

b

)


GOST-R Certified.

Warranty: Effective January 1, 2008, all N-TRON products carry a 3 year limited warranty from the date of purchase.