The Port screen contains the following commands:
Port Enable
Enable/Disable the port. (Select Enable to enable the port.)
Admin Status
Set Administration level. (Select UP to enable management
through the port.)
Both settings must be enabled to enable the port.
Port Speed Ctrl
Set the port manually or for Auto Negotiation.
Advertise Ctrl
This is the Selective Advertising feature. Selective Advertising,
when used in combination with Auto Negotiation, advertises the
configured speed and duplex mode for the twisted pair ports.
Auto Negotiation must be enabled for Selective Advertising.
NOTE
Selective Advertising must be used when connecting to a device that auto negotiates and a
specific speed and duplex mode is desired.
Using iView
2
iView² is IMC Networks’ management software, providing network management in
an easy to use GUI. Once iView² is installed on a network management PC using a
Windows operating system, use the Start menu to access iView².
NOTE
Windows SNMP services must be installed to receive traps.
The autoscan feature of iView² will detect IMC Network devices on an active subnet
and list them in the network outline. Click the connection for the IE-MultiWay to
open its iView² screen. To perform additional configuration, select the iView
2
iConfig
view icon on the toolbar in iView². This allows a session to be launched, and the
default password/username is admin/admin. Additional private usernames and
passwords can be entered in the USERS tab. If the list of passwords is not
maintained, the usernames and passwords can be reset by opening a CLI session and
typing in the cleandb command. This will reset all but the IP address of the device.