Wiring the power inputs, Wiring the fault alarm contact – B&B Electronics EIRP410-2SFP-T - Manual User Manual

Page 15

background image

Manual Documentation Number: EIRP410-2SFP-T-0912m

11

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Wiring the Power Inputs

Wiring the Fault Alarm Contact

The fault alarm contact wired to pins 3 and 4 of the terminal block connector as the picture shows below. When the wires

are inserting the connected device will detect the fault status. The fault status includes power failure or port link failure.

Once one of the mentioned states occur an open circuit will exist. An application example for the fault alarm contact is

shown on the next page:

Note

The wire gauge for the terminal block should be in the range between
12-24 AWG.