Status register commands, 1 read status register – Rainbow Electronics AT25DL081 User Manual
Page 35

35
AT25DL081 [DATASHEET]
8732D–DFLASH–12/2012
11.
Status Register Commands
11.1 Read Status Register
The two-byte Status Register can be read to determine the device’s ready/busy status, as well as the status of many
other functions such as hardware locking and software protection. The Status Register can be read at any time, including
during an internally self-timed program or erase operation.
To read the Status Register, the CS pin must first be asserted and then the opcode 05h must be clocked into the device.
After the opcode has been clocked in, the device will begin outputting Status Register data on the SO pin during every
subsequent clock cycle. After the second byte of the Status Register has been clocked out, the sequence will repeat
itself, starting again with the first byte of the Status Register, as long as the CS pin remains asserted and the clock pin is
being pulsed. The data in the Status Register is constantly being updated, so each repeating sequence may output new
data. The RDY/BSY status is available for both bytes of the Status Register and is updated for each byte.
At clock frequencies above f
CLK
, the first two bytes of data output from the Status Register will not be valid. Therefore, if
operating at clock frequencies above f
CLK
, at least four bytes of data must be clocked out from the device in order to read
the correct values of both bytes of the Status Register.
Deasserting the CS pin will terminate the Read Status Register operation and put the SO pin into a high-impedance
state. The CS pin can be deasserted at any time and does not require that a full byte of data be read.
Notes: 1. Only bit 7 of Status Register Byte 1 will be modified when using the Write Status Register Byte 1 command.
2. R/W = Readable and Writeable
R = Readable only
Table 11-1. Status Register Format – Byte 1
Bit
Name
Type
Description
7
SPRL
Sector Protection Registers
Locked
R/W
0
Sector Protection Registers are unlocked (default)
1
Sector Protection Registers are locked
6
RES
Reserved for future use
R
0
Reserved for future use
5
EPE
Erase/Program Error
R
0
Erase or program operation was successful
1
Erase or program error detected
4
WPP
Write Protect (WP) Pin Status
R
0
WP is asserted
1
WP is deasserted
3:2
SWP
Software Protection Status
R
00
All sectors are software unprotected
(all Sector Protection Registers are 0)
01
Some sectors are software protected. Read
individual Sector Protection Registers to determine
which sectors are protected.
10
Reserved for future use
11
All sectors are software protected
(all Sector Protection Registers are 1 – default)
1
WEL
Write Enable Latch Status
R
0
Device is not write enabled (default)
1
Device is write enabled
0
RDY/BSY
Ready/Busy Status
R
0
Device is ready
1
Device is busy with an internal operation