Dc and ac operating range, Operating modes, Dc characteristics – Rainbow Electronics AT29LV512 User Manual
Page 5
![background image](/manuals/281581/5/background.png)
5
AT29LV512
0177M–05/02
Notes:
1. After power is applied and V
CC
is at the minimum specified data sheet value, the system should wait 20 ms before an
operational mode is started.
Notes:
1. X can be V
IL
or V
IH
.
2. Refer to AC Programming Waveforms.
3. V
H
= 12.0V ± 0.5V.
4. Manufacturer Code is 1F. The Device Code is 3D.
5. See details under Software Product Identification Entry/Exit.
DC and AC Operating Range
AT29LV512-12
AT29LV512-15
AT29LV512-20
AT29LV512-25
Operating
Temperature (Case)
Com.
0°C - 70°C
0°C - 70°C
0°C - 70°C
0°C - 70°C
Ind.
-40°C - 85°C
-40°C - 85°C
-40°C - 85°C
-40°C - 85°C
V
CC
Power Supply
(1)
3.3V
± 0.3V
3.3V
± 0.3V
3.3V
± 0.3V
3.3V
± 0.3V
2.
Not recommended for New Designs.
Operating Modes
Mode
CE
OE
WE
Ai
I/O
Read
V
IL
V
IL
V
IH
Ai
D
OUT
Program
(2)
V
IL
V
IH
V
IL
Ai
D
IN
Standby/Write Inhibit
V
IH
X
(1)
X
X
High Z
Program Inhibit
X
X
V
IH
Program Inhibit
X
V
IL
X
Output Disable
X
V
IH
X
High Z
Product Identification
Hardware
V
IL
V
IL
V
IH
A1 - A15 = V
IL
, A9 = V
H
(3)
, A0 = V
IL
Manufacturer Code
(4)
A1 - A15 = V
IL
, A9 = V
H
(3)
, A0 = V
IH
Device Code
(4)
Software
(5)
A0 = V
IL
Manufacturer Code
(4)
A0 = V
IH
Device Code
(4)
DC Characteristics
Symbol
Parameter
Condition
Min
Max
Units
I
LI
Input Load Current
V
IN
= 0V to V
CC
1
µA
I
LO
Output Leakage Current
V
I/O
= 0V to V
CC
1
µA
I
SB1
V
CC
Standby Current CMOS
CE = V
CC
- 0.3V to V
CC
Com.
40
µA
Ind.
50
µA
I
SB2
V
CC
Standby Current TTL
CE = 2.0V to V
CC
1
mA
I
CC
V
CC
Active Current
f = 5 MHz; I
OUT
= 0 mA; V
CC
= 3.6V
15
mA
V
IL
Input Low Voltage
0.6
V
V
IH
Input High Voltage
2.0
V
V
OL
Output Low Voltage
I
OL
= 1.6 mA; V
CC
= 3.0V
0.45
V
V
OH
Output High Voltage
I
OH
= -100 µA; V
CC
= 3.0V
2.4
V