Figure 17, Table 8, Attiny11/12 – Rainbow Electronics ATtiny12 User Manual
Page 19

19
ATtiny11/12
1006C–09/01
Figure 17. Reset Logic for the ATtiny12
Note:
1. The Power-on Reset will not work unless the supply voltage has been below V
POT
(falling).
Table 8. Reset Characteristics for the ATtiny12
Symbol
Parameter
Condition
Min
Typ
Max
Units
V
POT
Power-on Reset Threshold
Voltage (rising)
BOD disabled
1.0
1.4
1.8
V
BOD enabled
0.6
1.2
1.8
V
Power-on Reset Threshold
Voltage (falling)
BOD disabled
0.4
0.6
0.8
V
BOD enabled
0.6
1.2
1.8
V
V
RST
RESET Pin Threshold
Voltage
0.6V
CC
V
V
BOT
Brown-out Reset Threshold
Voltage
(BODLEVEL = 1)
1.5
1.8
1.9
V
(BODLEVEL = 0)
2.6
2.7
2.8
MCU Status
Register (MCUSR)
Brown-out
Reset Circuit
BODEN
BODLEVEL
Delay Counters
CKSEL[3:0]
CK
Full
WDRF
BORF
EXTRF
PORF
DATA BUS
Power-on Reset
Circuit
On-chip
RC Oscillator
See also other documents in the category Rainbow Electronics Sensors:
- MAX5151 (16 pages)
- MAXQ3108 (64 pages)
- MAX5661 (39 pages)
- MAX6691 (7 pages)
- MAX5362 (12 pages)
- ADC10158 (26 pages)
- MAX8922L (14 pages)
- MAX8596Z (8 pages)
- MAX7491 (18 pages)
- MAX15040 (15 pages)
- MAX5177 (16 pages)
- ADC08138 (22 pages)
- MAX5961 (42 pages)
- T89C51RD2 (86 pages)
- MAX16055 (9 pages)
- MAX6659 (17 pages)
- ADC0820 (20 pages)
- MAX6678 (19 pages)
- MAX8884Z (15 pages)
- MAX16915 (9 pages)
- MAX8620 (18 pages)
- MAX5144 (12 pages)
- MAX6670 (8 pages)
- MAX8760 (39 pages)
- W78C32C (14 pages)
- MX7533 (8 pages)
- MAX8727 (13 pages)
- MAX9053 (15 pages)
- W78C54 (16 pages)
- MAX8614B (15 pages)
- W90N740 (219 pages)
- MAX6626 (13 pages)
- ADC10738 (30 pages)
- MAX17000 (31 pages)
- MAX5051 (21 pages)
- MAXQ1004 (18 pages)
- MAX6871 (51 pages)
- MX7847 (12 pages)
- MAX6608 (6 pages)
- MAX17083 (15 pages)
- MAX6641 (17 pages)
- MAX5251 (16 pages)
- MAX6338 (8 pages)
- MAX6690 (16 pages)
- MAX8668 (18 pages)