Absolute maximum ratings, D.c. characteristics, A.c. characteristics – Rainbow Electronics HT24LC08 User Manual
Page 2: Ht24lc08
Absolute Maximum Ratings
Operating Temperature (Commercial) ........................................................................................................ 0
°C to 70°C
Storage Temperature ............................................................................................................................
-50°C to 125°C
Applied VCC Voltage with Respect to VSS ...............................................................................................
-0.3V to 6.0V
Applied Voltage on any Pin with Respect to VSS
........................................................................................................
-0.3V to V
CC
+0.3V
Note: These are stress ratings only. Stresses exceeding the range specified under
²Absolute Maximum Ratings² may
cause substantial damage to the device. Functional operation of this device at other conditions beyond those
listed in the specification is not implied and prolonged exposure to extreme conditions may affect device reliabil-
ity.
D.C. Characteristics
Ta=0
°C to 70°C
Symbol
Parameter
Test Conditions
Min.
Typ.
Max.
Unit
V
CC
Conditions
V
CC
Operating Voltage
¾
¾
2.2
¾
5.5
V
I
CC1
Operating Current
5V
Read at 100kHz
¾
¾
2
mA
I
CC2
Operating Current
5V
Write at 100kHz
¾
¾
5
mA
V
IL
Input Low Voltage
¾
¾
-1
¾
0.3V
CC
V
V
IH
Input High Voltage
¾
¾
0.7V
CC
¾
V
CC
+0.5
V
V
OL
Output Low Voltage
2.4V
I
OL
=2.1mA
¾
¾
0.4
V
I
LI
Input Leakage Current
5V
V
IN
=0 or V
CC
¾
¾
1
mA
I
LO
Output Leakage Current
5V
V
OUT
=0 or V
CC
¾
¾
1
mA
I
STB1
Standby Current
5V
V
IN
=0 or V
CC
¾
¾
5
mA
I
STB2
Standby Current
2.4V
V
IN
=0 or V
CC
¾
¾
4
mA
C
IN
Input Capacitance (See Note)
¾
f=1MHz 25
°C
¾
¾
6
pF
C
OUT
Output Capacitance (See Note)
¾
f=1MHz 25
°C
¾
¾
8
pF
Note: These parameters are periodically sampled but not 100% tested
A.C. Characteristics
Ta=0
°C to 70°C
Symbol
Parameter
Remark
Standard Mode*
V
CC
=5V
±10%
Unit
Min.
Max.
Min.
Max.
f
SK
Clock Frequency
¾
¾
100
¾
400
kHz
t
HIGH
Clock High Time
¾
4000
¾
600
¾
ns
t
LOW
Clock Low Time
¾
4700
¾
1200
¾
ns
t
R
SDA and SCL Rise Time
Note
¾
1000
¾
300
ns
t
F
SDA and SCL Fall Time
Note
¾
300
¾
300
ns
t
HD:STA
START Condition Hold Time
After this period the first
clock pulse is generated
4000
¾
600
¾
ns
t
SU:STA
START Condition Setup Time
Only relevant for repeated
START condition
4000
¾
600
¾
ns
t
HD:DAT
Data Input Hold Time
¾
0
¾
0
¾
ns
t
SU:DAT
Data Input Setup Time
¾
200
¾
100
¾
ns
t
SU:STO
STOP Condition Setup Time
¾
4000
¾
600
¾
ns
HT24LC08
Rev. 1.20
2
November 4, 2002