ing the VOUT_TRANSITION_RATE slew rate. Final
accuracy of V

OUT

is assured by the closed-loop volt-

age control.

This value is dimensionless.

The default VOUT_SCALE_LOOP value is 00h.

The VOUT_SCALE_LOOP command is ignored in feed-
back mode.

VOUT_OV_FAULT_LIMIT (40h)

The VOUT_OV_FAULT_LIMIT command sets the value
of the output voltage measured across RS_+ and RS_-,
which causes an output overvoltage fault.

The two data bytes are in DIRECT format. Valid values
are the same as VOUT_COMMAND.

The default VOUT_OV_FAULT_LIMIT value is 00h.

In response to the VOUT_OV_FAULT_LIMIT being
exceeded, the MAX16064:

1)

Sets the VOUT_OV bit in the STATUS_BYTE.

2)

Sets the VOUT_OV bit in the STATUS_WORD.

3)

Sets bit 5 (low byte) and bit 7 (high byte) of the
STATUS_WORD.

4)

Sets the VOUT Overvoltage Fault bit in the STA-
TUS_VOUT.

5)

Sets the VOUT_OV bit in the MFR_STATUS_WORD
register.

6)

Responds as specified by VOUT_OV_FAULT_
RESPONSE bits in the MFR_FAULT_RESPONSE
register.

7)

Notifies the host through SMBALERT assertion.

VOUT_OV_WARN_LIMIT (42h)

The VOUT_OV_WARN_LIMIT command sets the value
of the output voltage measured across RS_+ and RS_-,

which causes an output voltage high warning. This
value is typically less than the output overvoltage
threshold in VOUT_OV_FAULT_LIMIT.

The two data bytes are in DIRECT format. Valid values
are the same as the VOUT_COMMAND.

The default VOUT_OV_WARN_LIMIT value is 00h.

In response to the VOUT_OV_WARN_LIMIT being
exceeded, the MAX16064:

1)

Sets the OTHER bit in the STATUS_BYTE.

2)

Sets the OTHER bit in the STATUS_WORD.

3)

Sets the VOUT bit in the STATUS_WORD.

4)

Sets the VOUT Overvoltage Warning bit in the
STATUS_VOUT.

5)

Sets the OV_WARN bit in the STATUS_MFR_SPECIFIC
register.

6)

Sets the OV_WARN bit in the MFR_STATUS_WORD
register.

7)

Sets the OTHER bit in the MFR_STATUS_WORD.

8)

Notifies the host using SMBALERT assertion.

VOUT_UV_WARN_LIMIT (43h)

The VOUT_UV_WARN_LIMIT command sets the value
of the output voltage measured across RS_+ and RS_-,
which causes an output-voltage low warning. This value
is typically greater than the output undervoltage fault
threshold in VOUT_UV_FAULT_LIMIT.

This warning is masked until the output voltage reaches
the programmed voltage at startup, and also during
turn-off when the power supply is disabled.

The two data bytes are in DIRECT format. Valid values
are the same as VOUT_COMMAND.

The default VOUT_UV_WARN_LIMIT value is 00h.

In response to violation of the VOUT_UV_WARN_LIMIT,
the MAX16064:

1)

Sets the OTHER bit in the STATUS_BYTE.

2)

Sets the OTHER bit in the STATUS_WORD.

3)

Sets the VOUT bit in the STATUS_WORD.

4)

Sets the VOUT Undervoltage Warning bit in the
STATUS_VOUT register.

5)

Sets the UV_WARN bit in the STATUS_MFR_SPE-
CIFIC register.

6)

Sets the UV_WARN bit in the MFR_STATUS_WORD
register.

7)

Sets the OTHER bit in the MFR_STATUS_WORD.

8)

Notifies the host using SMBALERT assertion.

MAX16064

±0.3% Accurate, Quad, Power-Supply Controller with
Active-Voltage Output Control and PMBus Interface

38

______________________________________________________________________________________

R

2

R

1

VO+

VO-

RS_-

RS_+

POWER

SUPPLY

MAX16064

LOAD

Figure 18. VOUT_SCALE_LOOP