Outline drawing, Ordering code, Th7834c – Rainbow Electronics TH7834C User Manual
Page 12
12
TH7834C
1997A–IMAGE–05/02
Figure 8. Timing Diagram For Exposure Time Control
Note:
It is better to have
Φ
A
falling/rising edge outside the useful readout period.
Outline Drawing
Note:
Antireflective window: reflection.
Less than 1% per side over 400 - 700 nm wavelength range.
All dimensions are in mm (except otherwise specified).
Ordering Code
The ordering code is TH7834CCC-RB
Table 7. Exposure Time Reduction Conditions
Parameter
Symbol
Value
Unit
Min.
Typ.
Max.
Antiblooming Diode Bias
VA
1-2
. VA
3-4
14
15.5
15
V
Antiblooming And Expose Time
Control
Period 1
Φ
A1-2
,
Φ
A3-4
to be adjusted
V
Period 2
9.5
10
10.5
V
Φ
P(1-2, 3,4)
Φ
A(1-2, 3,4)
Antiblooming
level
0V
Period 2
Clear period
Period 1
∆
t
≥
20ns
≥
TR
TR = Readout period
integration time ti
2.54
±
0
.25
1.27
±
0
.25
7.50
±
0
.10
3.2
4.2
4.35
±
0
.45
88.0 ±0.88.
5.00
0.10
±
Y
X
1st pixel
pixel 12000
|Y12000-Y1|
≤ 150 µ
m
15.24 ±0.25
Z=1.80±0.30
1.10
±
0
.10
3.
15
±0
.32
2.12
±
0.2
7
68.58
0.25
(2.54
±
× 27)
9.71
0.6
±
PIXEL 1 MARK
2
3
1
1
2
3
Window
Photosensitive area
Optical distance between
external face of window