Absolute Maximum Ratings
Parameters
Symbol
Min.
Max.
Unit
Supply voltage
V
S
5
V
Power dissipation
P
tot
100
mW
Junction temperature
T
j
150
°
C
Storage temperature
T
stg
-55
125
°
C
Ambient temperature
T
amb
-55
125
°
C
Thermal Resistance
Parameters
Symbol
Value
Unit
Junction ambient
R
thJA
170
K/W
Electrical Characteristics
V
S
= 2.0 V to 4.0 V, T
amb
= -40°C to 125°C unless otherwise specified.
Typical values are given at V
S
= 3.0 V and T
amb
= 25°C. All parameters are refered to GND (Pin 7).
Parameters
Test Conditions
Symbol
Min.
Typ.
Max.
Unit
Supply current
Power down,
V
ENABLE
< 0.25 V, -40°C to 85°C
V
PA_ENABLE
< 0.25 V, -85°C to +125
°
C
V
PA_ENABLE
< 0.25 V, 25°C
(100% correlation tested)
I
S_Off
<10
350
7
nA
µ
A
nA
Supply current
Power up, PA off, V
S
= 3 V
V
ENABLE
> 1.7 V, V
PA_ENABLE
< 0.25 V
I
S
3.6
4.6
mA
Power up, V
S
= 3.0 V
V
ENABLE
> 1.7 V, V
PA_ENABLE
> 1.7 V
I
S_Transmit
8.5
11
mA
Output power
V
S
= 3.0 V, T
amb
= 25
°
C
f = 868.3 MHz, Z
Load
= (166 + j226)
W
P
Ref
3.5
5.5
8
dBm
Output power variation for the full
temperature range
T
amb
= -40°C to +85
°
C
V
S
= 3.0 V
V
S
= 2.0 V
D
P
Ref
D
P
Ref
-1.5
-4.0
dB