Read operation dc characteristics, Read operation ac characteristics – Rainbow Electronics W27E040 User Manual
Page 6
W27E040
- 6 -
READ OPERATION DC CHARACTERISTICS
(V
CC
= 5.0V
±
10%, T
A
= 0 to 70
°
C)
PARAMETER
SYM.
CONDITIONS
LIMITS
UNIT
MIN.
TYP.
MAX.
Input Load Current
I
LI
V
IN
= 0V to V
CC
-5
-
5
µ
A
Output Leakage Current
I
LO
V
OUT
= 0V to V
CC
-10
-
10
µ
A
V
CC
Standby Current
I
SB
CE = V
IH
-
-
1.0
mA
I
SB1
CE = V
CC
±
0.2V
-
5
100
µ
A
V
CC
Operating Current
I
CC
CE = V
IL
I
OUT
= 0 mA
f = 5 MHz
-
-
30
mA
V
PP
Operating Current
I
PP
V
PP
= V
CC
-
-
10
µ
A
Input Low Voltage
V
IL
-
-0.3
-
0.8
V
Input High Voltage
V
IH
-
2.0
-
V
CC
+0.5
V
Output Low Voltage
V
OL
I
OL
= 2.1 mA
-
-
0.4
V
Output High Voltage
V
OH
I
OH
= -0.4 mA
2.4
-
-
V
V
PP
Operating Voltage
V
PP
-
V
CC
-0.7
-
V
CC
V
READ OPERATION AC CHARACTERISTICS
(V
CC
= 5.0V
±
10%, T
A
= 0 to 70
°
C)
PARAMETER
SYM.
W27E040-90
W27E040-12
UNIT
MIN.
MAX.
MIN.
MAX.
Read Cycle Time
T
RC
90
-
120
-
nS
Chip Enable Access Time
T
CE
-
90
-
120
nS
Address Access Time
T
ACC
-
90
-
120
nS
Output Enable Access Time
T
OE
-
40
-
55
nS
OE High to High-Z Output
T
DF
-
30
-
30
nS
Output Hold from Address Change
T
OH
0
-
0
-
nS
Note: V
CC
must be applied simultaneously or before V
PP
and removed simultaneously or after V
PP
.