beautypg.com

Alarm controls, Alarm controls -6, 9363 function submenu list and descriptions – Cobalt Digital COMPASS 9363 Multi-Format Reference Generator User Manual

Page 30

background image

3

9363 Function Submenu List and Descriptions

3-6

9363 PRODUCT MANUAL

9363-OM (V1.2)

(continued)

• Audio Output Co-Timing Source Select

Selects the card output to which the AES or word clock output is
referenced.

Note: Any offset applied to the output using the Horizontal/Vertical

Offset Controls is applied to the AES/word clock output.

• AES Audio Output Level Controls

When AES output is used, provides level, mute, and audio tone frequency
controls.

Alarm Controls

Provides controls for setting DashBoard card status
alarms indicating processing status conditions.

• Reference Alarm

With Reference Alarm checked, conditions related to received reference status are propagated to the DashBoard card signal
status display (in this example, no reference signal received on selected input reference).

• Color Burst Presence Alarm

With Color Burst Detection checked, if selected received reference does not contain color burst, this status is propagated to
the DashBoard card signal status display (in this example, a black burst signal is being received on selected input reference).

• Output Incompatibility Alarm

With Video Output Compatibility for output channel checked, if selected output format on corresponding output channel is
incompatible with received (or selected internal) reference, this status is propagated to the DashBoard card signal status
display.

Table 3-1

9363 Function Submenu List — continued

AES Level sets output level (in dBFS; default is -20 dBFS sine wave).

AES Tone selects from the frequencies shown, and mute.

Note: Mute setting simply mutes the audio tone on the AES signal.

The output is a valid functional AES signal in all other