Sweep flight back shield assembly, Assembly – Grain Systems Unload Augers PNEG-1050 User Manual
Page 25
25
12" & 14" Commercial Bin Sweep Augers PNEG-1050
Assembly
5/8" Non-
Locknuts
Drive Unit
Reducer
Mount Plate
Sweep Back
Shield End
Plate
(3) Truss
Cable
(6) Saddle Portion
Of Cable Clamp
U-Bolt Portion
of Cable Clamp
(1) Eyebolt
(4) Cable
Take -Up
Bracket
5. SWEEP FLIGHT BACK SHIELD ASSEMBLY
Truss Cable Take-Up Detail
(as viewed from the top)
FIG.13
1.
Install eyebolt (1) through anchor on cable take-up
bracket (4), using flat washer and two 5/8" hex nuts.
(See Fig. 13)
2.
Install the cable anchor (5) to the outside of the back
shield using the existing hardware provided for the
shield. (See Fig. 14.)
3.
Attach truss cable (3) to cable anchor (5) using two
cable clamps (6). (See Fig. 14)
4.
Route the truss cable (3) through the small tube at the
end of the truss stand(s). (See Fig. 12 on page 24)
D. Inspect “DANGER” decal on back shield. If
decal cannot be easily read or is missing,
order a new one immediately from your
dealer or the manufacturer.
Secure the clamp u-bolts against the loose end of
the cable. (See Fig. 13)
Flat Washer
Cable
Clamps
Flighting with
Cutback
(4) Cable
Take-Up
Bracket
5/8" Non-
Locknuts
Flat
Washer
Eyebolt
3/8" x 1-1/2" HHCS with
Flat Washer and Locknut
5/8" x 4" HHCS
with Locknut
Shield
Mount
Plate
C. Truss Cable Assembly. (For units without cable
truss, go to step D.)
Truss Cable Anchor Detail
(as viewed from the top)
FIG.14
(6) Saddle Portion
of Cable Clamp
(6) U-Bolt Portion of
Cable Clamp
Bearing Stand
Sweep Shield
(Farthest from Drive End)
Sweep Tractor
(5) Cable Anchor
(3) Truss Cable
5.
Attach truss cable (3) to eyebolt (1) using two cable
clamps (6). (See Fig. 13)
6.
Using the eyebolt (1), tighten the truss cable (3) until
it is reasonably snug.
Shield Mount Plate
U-Bolts