Electrical cord support stand, Assembly – Grain Systems Unload Augers PNEG-1050 User Manual
Page 18
18
12" & 14" Commercial Bin Sweep Augers PNEG-1050
Assembly
1. Fasten electrical cord support stand (1) to the side of
the motor mount support (2) with two 1/2" x 1-1/2" hex
head capscrews, flat washers, and locknuts.
2. Install electrical cord clamp (3) into plate (4) on
support stand. Secure in place with the jam nut (7)
provided with the clamp.
2. ELECTRICAL CORD SUPPORT STAND
(Refer to Fig. 5.)
(1) Electrical Cord
Support Stand
(2) Motor Mount
Support
(3) Electrical Cord
Clamp
(5) Electrical Cord
(6) Motor Junction Box
(7) Jam Nut for
Cord Clamp
Route Cord Through
Ring on Top of
Support Stand
Output Shaft for
Connection to
Flight Shaft
Leave a Small Loop of
Cord Between Clamp
and Junction Box
Motor
Mount
Plate
(4) Plate
(8) Motor
Belt Guard
SIDE VIEW
END VIEW
FIG. 5
1/2" x 1-1/2"
HHCS, Flat
Washers, &
Locknuts
3. Route the electrical cord (5) from the electrical junction
box (6) through the electrical cord clamp (3) on the
support stand then through the ring on the top of the
support stand.
4. Leave a small loop of electrical cord between the cord
clamp (3) on the support stand and the electrical
junction box (6) on the outside of the motor (8).
Tighten the clamp on the electrical cord clamp to
secure the cord to the support stand.