Chapter 7: power supply – Grain Systems PNEG-1891 User Manual
Page 49

Table 7-1 Specifications for the electrical load on a portable dryer (cont'd.)
Dryer
model
Voltage
Motor
HP
Fuel Load
Amps
Maximum amps
with auxiliaries
Minimum
amps
Recommended
service in amps
Branch breaker
in amps
1226
2140
3 PH 220V
Load auger
10
26
271
149
350
90
Unload auger
10
26
90
Top Fan
25
64
90
Bottom Fan
10 to 12
33
60
(2) Auxiliary
(2) 15
78
*
3 PH 440V
Load auger
10
13
144
77.5
200
60
Unload auger
10
13
60
Top Fan
25
32
60
Bottom Fan
10 to 12
16.5
60
(2) Auxiliary
(2) 15
39
*
1214S
2141
1 PH 230V
Load auger
5
26
252
148
350
100
Unload auger
5
26
100
(2) Fans
(2) 10 to
12
96
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Load auger
5
13.2
176
92.4
225
60
Unload auger
5
13.2
60
(2) Fans
(2) 10 to
12
66
60
(2) Auxiliary
(2) 10
52
*
3 PH 440V
Load auger
5
6.6
93
46.2
150
60
Unload auger
5
6.6
60
(2) Fans
(2) 10 to
12
33
60
(2) Auxiliary
(2) 10
26
*
1218S
2181
1 PH 230V
Load auger
5
26
252
148
350
100
Unload auger
5
26
100
(2) Fans
(2) 10 to
12
96
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Load auger
5
13.2
165
82.4
225
60
Unload auger
5
13.2
60
(2) Fans
(2) 10
56
60
(2) Auxiliary
(2) 10
52
*
3 PH 440V
Load auger
5
6.6
87
41.2
150
60
Unload auger
5
6.6
60
(2) Fans
(2) 10
28
60
(2) Auxiliary
(2) 10
26
*
Pneg-1891 Portable Dryers
49