Chapter 6: Stiffeners

Close-Punch Connection for a Two-Ring Stiffener (0–14 Ga) to a
Base Stiffener (2–8 Ga)

Reference the following information when connecting a two-ring stiffener (CTS-2073XX) to a base stiffener
(CTS-2119XX).

Figure 6-14 Two-Ring Stiffener (0–14 Ga) to a Two-Ring Stiffener (2–8 Ga) Close-Punch Connection

A

Close-punch two-ring stiffener (CTS-2073XX)

B

Close-punch base stiffener (CTS-2119XX)

C

Splice (CTS-2091XX)

D

3/8 x 1 Bolt (S-7485)

E

3/8 Nut (S-9426)

F

Completed assembly

NOTE: Two-post stiffeners shown. The bolt pattern will

vary for three-post. Only place bolts where holes
in the stiffeners align with holes in the sidewall
sheet.

Two-Ring Stiffener (0–14 Ga) to a Base Stiffener (10–16 Ga)
Connection

Reference the following information when connecting a two-ring stiffener (CTS-2063XX) to a base stiffener
(CTS-2123XX).

Figure 6-15 Two-Ring Stiffener (0–14 Ga) to a Base Stiffener (10–16 Ga) Connection

A

Two-ring stiffener (CTS-2063XX)

B

Base stiffener (CTS-2123XX)

C

Splice (CTS-2091XX)

D

3/8 x 1 Bolt (S-7485)

E

3/8 Nut (S-9426)

F

Completed assembly

NOTE: Two-post stiffeners shown. The bolt pattern will

vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.