beautypg.com

Attaching the a-frames to the center collar – Grain Systems Tanks PNEG-4060 User Manual

Page 105

background image

Chapter 7: Roof Assembly

• Always practice safety when assembling rafter sections. Be aware of others around you when

moving long A-frame sections.

• Use evenly distributed connection points of support when lifting.

• Before attempting a lift, adjust each lifting cable to achieve the appropriate angle needed (approxi-

mately 30 degrees).

• Assemble the A-frames with X-bracing last, so that they can be easily accessed to be lifted into place

first.

Table 7-3 For standard roof

Bin Diameter

Peak Capacity

Ground Snow Load

Approximate A-Frame Weight

60 ft. (18.29 m)

20 K

40 PSF

370 lb (168 kg)

The part variance multiplier is 4%.

Attaching the A-Frames to the Center Collar

The A-frame rafters must be installed to support the center collar and main roof structure.

Before You Begin
The center collar should be assembled and secured to the support pole, and the A-frame rafters should be
assembled. Determine the correct location of each A-frame. For more information, see

Center Collar

Placement , page 102

. Read and understand the safe and proper lifting procedures needed to install the

A-frames. For more information, see

Guidelines for Assembling and Lifting the A-Frame Rafter Sections,

page 104

.

1. Carefully lift the A-frame assembly (A) into position, and align with the proper holes on the center

collar (B).

2. Install flange bolts (C) and flange nuts (D) as shown.

3. Before continuing with the remaining A-frame rafters, secure the A-frame rafter to the eave clip. See

Attaching the A-Frame to the Eave Bracket , page 106

.

Pneg-4060 60 Ft Diameter 40-Series Bin