5. Operating Controls
PNEG-1797CE CE Approved T-Series Tower Dryer
31
1. CONTROL POWER switch turns ON/OFF power to the control.
2. FAN switch starts/stops the fan. AUTO position is not used on T-Series and F-Series dryers.
3. HEATER switch turns the heater ON/OFF. AUTO position is not used on T-Series and
F-Series dryers.
4. LOAD AUGER switch selects operating mode wet fill conveyor. In AUTO and MANUAL, the wet fill
conveyor operates to keep the dryer full. In AUTO only the dryer shuts down if it is low on grain for a
pre-set period.
5. UNLOAD switch controls ‘Accutrol’ metering system and unload conveyor. In MANUAL, the
metering system operates at the speed set by the METERING ROLL SPEED switch. In AUTO, it runs
in multi-speed mode, controlled by the automatic moisture control.
6. OUTSIDE LIGHT switch controls the service light. In AUTO, the light is ON while the dryer is running
and OFF when shut down.
7. START switch starts and operates the dryer.
8. STOP switch stops all dryer functions except the blower which will continue to run for 15 minutes after
the stop has been pressed. To stop the blower before this time, turn the BLOWER switch to OFF.
The STOP switch is also used to re-set after a shut down.